11 - 3
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example:
Example #1:What is the range of possible values for Codabar
Coding Enable?
Enter:
cbrena*.
Response:
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example:
Example #2: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response:
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example:
Example #3: What is the device’s current setting for Codabar
Coding Enable?
Enter:
cbrena?.
Response:
CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example:
Example #4: What are the device’s settings for all Codabar
selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Summary of Contents for 5010
Page 1: ...5X10 5X80 5010 80 5110 80 5310 80 User s Guide ...
Page 54: ...4 26 ...
Page 62: ...5 8 ...
Page 68: ...6 6 ...
Page 124: ...7 56 ...
Page 152: ...10 6 ...
Page 178: ...11 26 ...
Page 182: ...12 4 ...
Page 190: ...A 6 ...
Page 191: ......
Page 195: ...OCR Programming Chart a e d g c h t l Discard Save r ...