Print Weight
Print Weight is used to adjust the way the imager reads Matrix symbols. If a
imager will be seeing consistently heavily printed matrix symbols, then a print
weight of 6 may improve the reading performance. For consistently light printing,
a print weight of 2 may help. After scanning the
Set Print Weight
bar code, set
the print weight (from 1-7) by scanning digits from the inside back cover, then
scanning
Save
.
Default = 4.
Video Reverse
Video Reverse is used to allow the imager to read bar codes that are inverted.
The “Off” bar code below is an example of this type of bar code. If additional
menuing is required, Video Reverse must be disabled to read the menu bar
codes and then re-enabled after menuing is completed.
Note: Images downloaded from the unit will not be reversed. This is a setting
for decoding only.
Set Print Weight
*
Default
On
*
Off
VIDREV0.