Honeywell Sensing and Control
3
Limitless™ WLS Series
Single Switch Adapter
ISSUE 1
50081314
Step 1: Each conductor color in the user-supplied cable needs to be connected to the end-user supplied switch as follows (see Fig-
ure 1 as an example):
BROWN
wire: Connect to
common
terminal of the user-supplied switch
BLACK
wire: Connect to
normally open
terminal of the user-supplied switch
BLUE
wire: Connect to
normally closed
terminal of the user-supplied switch
Figure 1. Limitless™ WLS Single Switch Adapter BT1 & BT2 Conductor to Switch
Step 2: Connect the mating connector w/cable to the WLS Single Switch Adapter M12 connector and then tighten
connector (see Figure 2)
Figure 2. WLS Single Switch Adapter BT1 & BT2 Connector to Mate Cable