Note: Batteries are not supplied with some panels
Number of Zone (detection) circuits
1 - Zone panel
2 - Zone panel
4 - Zone panel
8 - Zone panel
Zone circuit voltage range
19V to 25.5V
Zone circuit load (maximum)
Maximum Quiescent current: 3.0mA per zone OR
EN54 compliance limitation: 32 devices OR
Maximum of 20 diode bases per zone
(Short circuit current limited to < 20mA)
Number of Sounder circuits
2
2
4
8
Sounder circuit (shared load)
0.5A per output, 1A max shared load
@ 24V +2V -2V with mains present
(24V +2V -4V battery only)
0.5A per output, 1A max shared load
@ 24V +2V -2V with mains present
(24V +2V -4V battery only)
Sounder circuit fuse
0.75A resettable
End-of-line unit
Zone circuit
: Capacitor (diode) unit
Sounder circuit
: 10K ohms resistor
OR Biploar Capacitor
Flush fixing kit
13270-29 (Cut out required 378mm wide x 245mm high x 60mm deep)
Colour
Front cover - Grey RAL 7000 (standard)
Assembled panel size
(in mm)
395 wide x 274 high x 87 deep
Weight (with batteries) approximate
5.8kg
5.8kg
5.8kg
6.2kg
Operating temperature and humidity
0 - 40
o
C low to +95% RH non condensing
Storage temperature and humidity
-5
o
C to +50
o
C low to +95% RH condensing
Standards
EN54 Part 2:1997 + AMD 1 (and include optional clauses 7.8, 7.10 & 7.11) plus
EN54 Part 4:1997 + AMD 1 and AMD 2
Approvals
BSI approval acquired
Emission
BS EN50081-1:1992: Part 1 Residential, Commercial & Light industry
Class B limits
Immunity
BS EN50130-4: 1996: Part 4 Alarm systems : Electromagnetic compatibility
Product family standard:
Immunity requirements for components of fire, intruder
and social alarm systems
IP rating (BS5490)
IP31 (indoor)
Knock-In cable entry points
13 - top & 13 - back
Terminal size
2.5mm
2
maximum
Battery standby with 1mA load per
zone and 1A total sounder alarm load
72hr standby plus 0.5hr with alarm load
Auxiliary contacts
(operates with fire)
Pair of normally closed (NC) and a pair of normally open (NO) contacts rated
1A @ 24V dc resistive load (Maximum
100m
cable distance)
Common Fault
Open collector - normally
On
(35mA limit)
Common Fire
Open collector - normally
Off
(16mA limit)
Class change
Normally open push button, up to
100m
cable distance away from the panel
24V Power supply
(Monitored)
250mA maximum at 24V dc +2V, -4V
500mA maximum at 24V dc +1.5V, -4V
User access: By means of code entry
via numeric key pad
(AL1 Authorised user - No code is
required)
AL2 Site security 3 digit code -
123
AL3 Site engineering 3 digit code -
321
AL4 Engineers 4 digit code -
7426
Reset AL2 & AL3 codes 4 digit code -
2623
Key pad button controls
Sound alarm, Silence alarm, System Reset & Cancel buzzer & numeric keypad.
Buzzer for local audible indications
Fire & System Fault - continuous sound Fault - intermittent sound
(via piezoelectric buzzer operating at 2 or 2.5KHz 70dB(A) at 1m)
Visual indications
FIRE & ZONES-fire
(Red LEDs ‘lights’)
ZONES-fault, Fault, System, Power, Earth, Sounder, Disable, Test, Power,
Access/Function
(Yellow LEDs ‘lights’)
Power on
(Green LED ‘lights’)
Delay (
Yellow LED ‘lights’
)
Repeat panel connections
via serial port, see also repeat panel specification
Fire Panels
Specification for the Control panel
4188-424 issue 4_Part 1_10-09
20
Specification for the Control panel