Fit the
gasket.
▷
Tighten the nuts in two cycles in a crosswise
fashion, torque: 46 Nm.
▷
When installing, ensure that the components
are sealed tightly.
▷
Ensure that no lateral forces act on the burner
recuperator.
Heat guard
▷
During operation, the burner body and eductor
or flue gas connector can reach surface tem-
peratures of over 80°C.
▷
We recommend that warning signs and a contact
guard be fitted, for example made of perforated
sheet metal.
▷
Do not insulate the burner body, eductor and flue
gas connector to prevent material overheating.
Connecting the gas and air pipes
Gas connection (GA) and air connection (LA)
LA
GA
Cooling air connection (KA)
▷
Optional intermediate flange with an additional
cooling air connection on the burner.
▷
To increase the air volume in cooling mode.
KA
Table of threaded and flanged connections
▷
Threaded connection to ISO 7, flange dimensions
to ISO 7005, PN 16.
Type
GA*
LA
KA
ECOMAX
®
0
R ½"
Rp 1"
Rp 1"
ECOMAX
®
1
R ½"
Rp 1"
Rp 1½"
ECOMAX
®
2
R ½"
Rp 1½"
Rp 1½"
ECOMAX
®
3
R ½"
Rp 2"
Rp 1½"
ECOMAX
®
4
R ¾"
Rp 2"
Rp 2"
ECOMAX
®
5
R 1"
Rp 2"
Rp 2"
ECOMAX
®
6
R 1½"
Rp 3"
N/A
* On the ECOMAX
®
..L for LCV gas, connections
may differ depending on the project specifications.
▷
Install flexible tubes or bellows units to prevent
mechanical stress or transmission of vibration.
▷
Ensure that the gaskets are undamaged.
DANGER
Risk of explosion! Ensure the connection is air-tight.
▷
The gas insert can be rotated in 90° steps if
necessary.
▷
We recommend that all the gaskets that are
removed to rotate the gas insert be replaced.
▷
The electrode must remain in its position at the
top left when the gas insert is rotated. The mixing
device (gas lance) must be rotated for this pur-
pose, see page 11 (Replacing the gas lance).
▷
If necessary, another air connection may be used.
The burner has three air connections, two of
which are sealed with blind flanges.
▷
Ensure undisturbed flow to the orifices in the air
and gas connections. The ECOMAX
®
is delivered
with a connection set for gas. In the air circuit,
we also recommend the use of a connection set
for air, see page 16 (Accessories).