Check whether the burner is adequately ground-
ed.
•
Check the electrode – see page 10 (Mainte-
!
Defective insulator on the electrode, ignition spark
jumps over incorrectly.
•
Check the electrode – depending on the burner
construction stage.
?
Burner flame ignites with a loud bang?
!
Incorrect electrode adjustment.
•
Check the electrode – depending on the burner
construction stage – see page 10 (Mainte-
nance).
!
Incorrect burner adjustment – air volume too low
or too high.
•
Correct the burner adjustment – see page 7
!
Incorrect burner adjustment – gas volume re-
leased too quickly, defective or incorrectly set
damping unit on the solenoid valve.
•
Check the solenoid valve.
•
Reduce the start gas rate.
•
Adjust the damping speed, see Operating in-
structions VAS, VCS, VAS..L.
•
ECOMAX
®
0C: if the burner still ignites with a
loud bang after the damping speed has been
adjusted, set pre-ventilation to 0.5 s using the
BCU (parameter 37).
!
Excessive central air volume for LPG operation.
•
Carefully restrict the central air at the adjust-
ing cock. Excessive restriction may cause soot
formation.
?
Burner performs a fault lock-out after burn-
ing faultlessly in normal operation?
!
Incorrect gas and air flow rate settings.
•
Check the gas and air pressures.
!
Automatic burner control unit signals a fault.
•
Check the ionization cable.
•
Check the ionization current. The ionization cur-
rent must be at least 5 µA – stable signal.
!
Mixing device or swirl plate soiled.
•
Clean gas and air bore holes and air slots.
•
Remove deposits from mixing funnel or swirl
plate.
!
Excessive pressure fluctuations in the furnace
chamber.
•
Ask Honeywell Kromschröder for control con-
cepts.
Accessories
Flue gas guide tube FGT set . .D
1
3
2
ECOMAX..M, ECOMAX..F
ECOMAX..C
1
3
2
Burner gasket
Flue gas guide tube FGT
Mounting gasket
For a direct heating system a flue gas guide tube FGT
is required.
The FGT set..D is not supplied with the ECOMAX
®
and must be ordered separately. If the FGT set..D
is ordered with the ECOMAX
®
, it will be supplied
ready-fitted on the burner.
Flue gas eductor EJEK
The eductor generates a negative pressure with a
centrally positioned nozzle and thus draws the flue
gases through the burner’s heat exchanger.
The EJEK is not included in the delivery and must be
ordered separately.