GB-13
D
GB
F
NL
I
E
Checking the body insulation
Burner with flue gas connector FLUP
1
2
3
Burner with eductor
1
2
3
4
Follow the reverse procedure when reassem-
bling.
▷
If possible, carefully check the body insulation
from the front for signs of damage.
26
5
If the insulation is worn or damaged, it must be
replaced.
Checking/replacing the air guide tube LFR
and recuperator
ECOMAX
®
. .C
CAUTION
Risk of breakage. The air guide tube and recu-
perator in the ECOMAX
®
..C are made of ceramic
material.
1
4
2
3
5
1
4
2
3
5
Check the
recuperator.
▷
If any ceramic components are damaged, they
must be replaced.
▷
To check the body insulation carefully and replace
the recuperator, remove the burner and suspend
it vertically, e.g. on two beams.
8
6
7
9
11
10
Checking the insulation
▷
If the insulation is worn or damaged, it must
be replaced.
8b
8c
8a
8d
b
a
Ensure that the
flue gas
insulation is
installed in the
correct position.
a < b
Remove the
body insula-
tion from the
front.