7. MAINTENANCE
52
E
THROTTLE CABLE ADJUSTMENT
1. Move the throttle lever [1] to the
fast position [2].
2. Remove air cleaner cover.
3. Measure clearance between
control choke arm [3] and control
lever [4]. Clearance should be
0 ~ 1 mm. If clearance is correct,
no adjustment is necessary. If
clearance is incorrect, proceed
to step 4.
4. Loosen lock nuts [5] with a
10 mm wrench. Move adjuster
[6] up or down as required to
achieve clearance in step 3.
Retighten locknuts [5].
ST
OP
ST
OP
[2]
[1]
0 ~ 1 mm
[3]
[4]
[5]
[6]