9-6
FLYWHEEL/IGNITION COIL
HRX217HYA • HRX217HZA
Push the ignition coil firmly toward the flywheel and tighten
the bolts securely.
Remove the feeler gauge, and then recheck the air gap again.
Install the fan cover (
).
CHARGE COIL AND DIODE TEST
HZA TYPE ONLY
1. Select the diode function of a digital multimeter.
2. Attach the
red
lead to the laminate core (ground) and the
black
lead to the charge coil terminal.
3. Check for the specified voltage drop.
Specified voltage
0.4 ~ 0.8 VDC
0.30 ~ 0.50 mm
(0.012 ~ 0.020 in)
0.30 ~ 0.50 mm
(0.012 ~ 0.020 in)
IGNITION COIL
DIODE
TEST
FUNCTION
RED TEST
LEAD
BLACK TEST LEAD
CHARGE COIL
TERMINAL
DIGITAL MULTIMETER, FLU-88
(commercially available)