TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible Cause
Correction
Air filter restricted.
Clean or replace air filter (see
page 57).
Bad fuel, generator stored
without draining gasoline, or
refueled with bad gasoline.
Drain fuel tank (see page 68).
Refuel with fresh gasoline (see
page 52).
Fuel filter restricted, fuel system
malfunction, fuel pump failure,
ignition malfunction, valves
stuck, etc.
Take the generator to your
servicing dealer, or refer to the
shop manual.
Possible Cause
Correction
OUTPUT indicator is OFF, and
OVERLOAD ALARM indicator is
ON.
Check AC load. Stop and restart
the engine.
Check the cooling air inlet. Stop
and restart the engine.
AC Circuit protector(s) tripped.
Check AC load and reset AC
circuit protector(s) (see page 18).
Faulty power tool or appliance.
Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator.
Take the generator to your
servicing dealer, or refer to the
shop manual.