EU-92
Date Revised: March 2021 (PSV52522-S)
© 1998-2021 American Honda Motor Co., Inc.—All Rights Reserved
EU M
o
dels
10A
10B
10.
Call Techline. Replace the stator.
Reassemble, then retest the generator
for normal output.
NG
Call Techline. Inspect the inverter. Replace the inverter if
it tests faulty. Reassemble, then retest the generator for
normal output.
11.
Test the generator using a load bank.
The generator must carry the rated
Maximum output:
120V, 7 kVA, 58.3 Amps
240V, 7 kVA, 29.1 Amps
Rated output:
120V, 5.5 kVA, 45.8 Amps
240V, 5.5 kVA, 22.9 Amps
Call Techline. Replace the GCU.
Reassemble, then retest the
generator for normal output.
Engine performance problem. Check
the following:
• Carbon deposits in combustion
chamber or spark arrester.
• Fuel system.
• Engine compression.
• Ignition system.
Repair as necessary and
repeat
OK
OK
NG
OK
NG
Call Techline.
OK
Problem is corrected; return the
unit to the customer. If the
problem reoccurs, the problem is
in the load or generator usage.
NG