![Honda Eu7000is Manual Download Page 12](http://html1.mh-extra.com/html/honda/eu7000is/eu7000is_manual_2156276012.webp)
EU-95
Date Revised: March 2021 (PSV52522-S)
© 1998-2021 American Honda Motor Co., Inc.—All Rights Reserved
EU Mo
dels
When you press the display button longer than 3
seconds on an error code, the display goes into a
detailed error log mode, and it shows the engine
run-time, generator output, engine speed,
inverter temperature, throttle angle, battery
voltage, engine temperature, outside air
temperature, barometric pressure, O2 sensor
voltage, and generator output in volt-amperes
(VA) for the incident in this sequence.
When END appears in this mode, press the
display button longer than 3 seconds to change
the display back to the error log mode.
Inverter output voltage (master) (V)
Inverter output voltage (slave) (V)
Inverter output amperage (master) (A)
Inverter output amperage (slave) (A)
Engine speed (rpm)
Inverter unit power module temperature
(master) (°C)
Inverter unit power module temperature
(slave) (°C)
Throttle valve angle (%)
Battery voltage (V)
End
Engine run time (hour)
h
V
A
A
rpm
V
V
V
A
V
Engine temperature (°C)
Ambient Air Temperature (°C)
Barometric Pressure (kPa
)
O2 sensor voltage (V)
Output (VA)
DETAILED ERROR LOG MODE: