11-4
dummyhead
dummyhead
OTHER ELECTRICAL
OIL LEVEL SWITCH INSPECTION
Remove the oil level switch (page 11-3).
Check continuity between the oil level switch wire
connector
and ground terminal
.
The oil level switch is normal if there is no continuity
with the switch set upside down.
There must be continuity between the wires with the
switch set right side up.
Suspend the switch in a container filled with oil and
check the float operation.
The switch is normal if there is continuity between the
wires initially, and no continuity when the switch is
immersed in the oil.
ENGINE STOP SWITCH INSPECTION
Remove the maintenance cover (page 5-2).
Disconnect the engine stop switch 2P connector
.
Check the continuity between the terminals at each
switch position.
Switch position
Terminal
ON
OFF
1 – 2
No continuity
Continuity
ENGINE STOP SWITCH
ON
OFF
Summary of Contents for EU10iT1