If Your PWC Is Submerged
Your PWC will not sink, but if it is
submerged or flooded with water, act quickly
to avoid severe engine damage.
1. Remove your PWC from the water.
2. Remove the bilge drain plugs to drain the
water out of the engine compartment.
3. Disconnect the ignition coil connectors and
ignition coils from the spark plugs.
4. Remove the spark plugs from the engine
and store them in a safe place and put the
soft cloths on the plug holes. Do not
connect the ignition coils to the ignition
coil connectors.
5. Disconnect the injector connectors.
6. Open the throttle fully.
7. Press the start button for 15 seconds.
Continue this procedure until water stops
coming out.
8. Remove the soft cloths and pour a
tablespoon (15
–
20cc) of clean engine oil
into each cylinder.
9. Push the start button several times to crank
the engine and distribute the oil.
After cleaning the spark plug holes,
reinstall the spark plugs and the ignition
coils.
Reconnect the ignition coil connectors and
the injector connectors.
Take your PWC to your Honda PWC
dealer as soon as possible.
Taking Care of the Unexpected
194
10.
11.
12.