12
EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS – ATTIC SPACE NOT ACCESIBLE
4. Remove metal fan brackets and light kit mount-
ing bar by unscrewing four screws on the light kit
mounting bar and two screws on each metal fan
bracket.
NOTE: Save screws for re-installation of fan
motor, brackets and light kit mounting bar.
5. With screws removed slide the brackets to the left
and then remove from the housing.
Remove the three prong fan plug from the
housing.
With the grille mounitng brackets removed, pull the
black fan unit straight out of the metal housing..
6. Pull the house wires through the wire box cover
hole. Using a quick connector, secure 120 V AC
house wiring from the wall switch to the fan as
showen in the wiring diagram on page 5. 14 AWB
is the smallest conductor that should be used for
branch-circuit wiring. Please refer to the wiring
diagrams for detail on page 5.
Carefully push the connect wires back into the
wiring box housing. Reattach the wiring box cover.
CAUTION:
If your electrical wires do not match
the colors listed, you must determine what each
house wire represents before connecting. You
may need to consult an electrical contractor to
determine safely.
6
Product
wires
House
wires
Quick
connector
5
4