10
www.homewerksww.com
EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS
6. Replace duct connector by hooking the connector
on one side of the metal flange opening on the
housing and then pressing down on the other side
to snap the connector into place. Ensure that all
four metal flanges on the housing are inside the
plastic duct connector when it is replaced.
7. Pull the house wires through the wire box cover
hole. Using a quick connector, secure 120 V
AC house wiring from the wall switch to the fan
as showen in the wiring diagram on page 5. 14
AWB is the smallest conductor that should be
used for branch-circuit wiring. Please refer to
the wiring diagrams for detail on page 5.
Carefully push the connect wires back into the
wiring box housing. Reattach the wiring box
cover.
CAUTION:
If your electrical wires do not match
the colors listed, you must determine what each
house wire represents before connecting. You
may need to consult an electrical contractor to
determine safely.
8. Install a circular 4 in. duct (not included) and
secure it with duct tape or clamps (neither
included).
Finish ceiling work. Ceiling hole should be aligned
with edge of fan body.
1. Screw threaded rod of LED light kit assembly to
the the threaded stud on the housing.
Plug the LED light kit to the plug on the housing.