-14-
ALFA IN a.s. ©
www.alfain.eu
Fig. 5 – Gas fitting
Pos.
Description
F1
Gas cylinder
F2
Cylinder valve
F3
Gas heater connector
F4
Pressure reducer
F5
High pressure manometer
F6
Low pressure manometer
F7
Adjusting screw
F8
Gas outlet
F9
Solenoid valve
F10
Chain
The gas cylinder cannot be fixed to the HOMER MG-160. It can be fixed onto
the welders cart or other fixing appliance according to the user´s manual of
such appliance and in accordance with the safety rules.
1. Connect the pressure reduction valve on the gas cylinder.
2. Connect the gas hose to gas outlet
F8
on the valve and the gas inlet on the
machine.
3. Open the
F2
cylinder valve.
4. Set the voltage switch
2
to the position
.
5. Adjust the amount of gas on the reduction gas valve (it is not a part of the
welding machine) by the
F7
adjusting screw.