Start-up
• Place the blind actuator onto the DIN rail (
see
figure 2
). Make sure that you can read the letters
on the device and display and that the connecting
terminals of channel 1 and 2 are at the top.
• Make sure that the catch spring engages properly
and that the device is securely seated on the rail.
• Wire the device according to the connecting
diagram in
figure 3
.
• Connect the phase conductor for the selected
channel to the corresponding terminal
(G)
(
see
figure 3
). Any types of phase conductors (L1,
L2, L3) can be connected to the power input
terminals.
• Connect the switched phase conductor to move
up the motor for the selected channel to the
corresponding terminal ( )
(H)
(
see figure 3
).
• Connect the switched phase conductor to move
down the motor for the selected channel to the
corresponding terminal ( )
(I)
(
see figure 3
).
The phase conductor connection is marked with
an arrow pointing to the centre of the device, the
switched phase conductor with an arrow point-
ing towards outside. To connect or loosen the
conductor, the white actuation lever at the top of