Page 7 — English
EXTENSION CORDS
When using a cultivator at a considerable distance from the
power source, use an extension cord heavy enough to carry
the current that the tool will draw. An undersized extension
cord will cause a drop in line voltage, resulting in a loss of
power and causing the motor to overheat. Use the chart
provided below to determine the minimum wire size required
in an extension cord. Only round jacketed cords listed by
Underwriter's Laboratories (UL) should be used.
**Ampere rating (on tool faceplate)
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
7.1-12.0 12.1-16.0
Cord Length
Wire Size (A.W.G.)
25'
16
16
16
16
14
14
50'
16
16
16
14
14
12
100'
16
16
14
12
10
—
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the tool outdoors, use an extension cord
that is designed for outside use. This is indicated by the
letters “WA” or “W” on the cord's jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the tines and working area.
Position the cord so that it will not get caught on lumber,
tools or other obstructions while you are working with a
cultivator. Failure to do so can result in serious personal
injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use tool with a damaged cord
since touching the damaged area could cause electrical
shock resulting in serious injury.
ELECTRICAL CONNECTION
This tool is powered by a precision built electric motor. It
should be connected to a
power supply that is 120 volts,
60 Hz, AC only (normal household current). Do not operate
this tool on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If
the product does not operate when plugged into an outlet,
double check the power supply.
SPEED AND WIRING
The speed is not constant and decreases under a load or
with lower voltage. For voltage, the wiring in a shop is as
important as the motor’s horsepower rating. A line intended
only for lights cannot properly carry a cultivator motor. Wire
that is heavy enough for a short distance will be too light
for a greater distance. A line that can support one cultivator
may not be able to support two or three tools.
FOR ALL DOUBLE-INSULATED APPLIANCES
Replacement Parts — When servicing use only identical
replacement parts.
Polarized Appliance Connections — To reduce the risk
of electric shock, this appliance has a polarized plug (one
blade is wider than the other) and will require the use of a
polarized extension cord. The appliance plug will fit into
a polarized extension cord only one way. If the plug does
not fit fully into the extension cord, reverse the plug. If the
plug still does not fit, obtain a correct polarized extension
cord. A polarized extension cord will require the use of a
polarized wall outlet. This plug will fit into the polarized wall
outlet only one way. If the plug does not fit fully into the wall
outlet, reverse the plug. If the plug still does not fit, contact
a qualified electrician to install the proper wall outlet. Do not
change the equipment plug, extension cord receptacle, or
extension cord plug in any way.
ELECTRICAL