![Homelite UT40520 Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/homelite/ut40520/ut40520_operators-manual_2153648013.webp)
Page 9 — English
FEATURES
KNOW YOUR WATER PUMP
See Figure 1.
The safe use of this product requires an understanding of
the information on the tool and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CHOKE LEVER
The choke is used when starting the engine.
ENGINE SWITCH
The engine switch is used either in combination with the
starter grip and rope to start the water pump.
FUEL LEVER
Fuel flow from the fuel tank to the engine is turned on and
off using the fuel lever.
FUEL TANK
This fuel tank has a maximum capacity of 0.95 gal. Use
unleaded automotive gasoline in the engine.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
water pump when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove
the oil drain plug to allow old engine lubricant to be drained.
PRIMING PORT
The priming port is used to prime the pump prior to operation.
STARTER GRIP AND ROPE
The starter grip and rope is used (along with the engine
switch) to start the water pump’s engine.
THROTTLE LEVER
The throttle lever is used to control the pump’s speed.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type ...................................................... 179cc OHV
Cooling System .................................................. Forced Air
Starting System .........................................................Recoil
Ignition System ............................................................ T.M.I
Spark Plug ................................................Torch/LG F6RTC
Engine Lubricant Volume............................20 oz. (0.63 qt.)
Fuel Volume ...........................................................0.95 gal.
PUMP
Port Diameter (Intake/Outlet) ........................................2 in.
Maximum Gallons Per Minute .............................. 158 gpm
Suction Head Lift .........................................................26 ft.
Total Head Lift .............................................................82 ft.
DIMENSIONS
Length .....................................................................18.8 in.
Width .......................................................................15.5 in.
Height ......................................................................16.1 in.
KEEP AT LEAST
20 FT. AWAY
CO Detector
in Living Areas
Only use OUTSIDE and
FAR AWAY
from windows,
doors, and vents.
Direct exhaust AWAY
from all windows, doors,
and vents.
LOCATE WATER PUMP AT LEAST 20 FT.* AWAY TO REDUCE THE
RISK OF CARBON MONOXIDE GETTING INSIDE THE HOME
*
Minimum distance as recommended by U.S. Department of Health and Human
Services Centers for Disease Control and Prevention (www.cdc.gov/co). Your specific
home and/or wind conditions may require additional distance.
Exhaust (CO)