Cleaning and Care

CAUTION:

 Before cleaning the unit, turn power off and unplug unit from the outlet.

To Clean the Tank

Remove the water tank from the humidifier base by lifting it 
from the main unit. Unscrew the tank cap and rinse inside the 
tank with clean water. (Fig. 7) To remove any scale or build 
up, use a 50/50 mixture of vinegar and lukewarm water to 
clean the inside of the tank. 

Suggestion:

 Clean the water tank once every two to three 

weeks, depending on your water conditions.

To Clean the Ultrasonic Membrane

Pour a 50/50 mixture of vinegar and water on the surface of 
the ultrasonic membrane, then soak for five minutes. Brush 
clean with a soft-bristle brush (not included) and rinse. 

NEVER

 touch the ultrasonic membrane with your fingers as 

the natural oils in skin can damage the membrane. (Fig. 8)

Suggestion:

 Clean the membrane once every two to three 

weeks, depending on your water conditions.

NOTE:

 Never submerge the base in water or any liquid

To Clean the Surface

Clean the surface of the unit with a clean damp soft cloth as 
often as needed. (Fig. 9)

Fig. 9

About White Dust:

Use of high mineral content hard water may cause a white mineral residue to accumulate on 
surfaces in the room near the humidifier. The mineral residue is commonly called “white dust.”  
The higher the mineral content (or, the harder your water is), the greater the potential for white 
dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals 
suspended in the water.

How and Why To Use Demineralization Cartridges:

The HoMedics demineralization cartridge will help reduce the potential for white dust, a 
deposit of minerals left behind from using hard water in your humidifier. The cartridge should 
be replaced every 30 – 40 fillings. The cartridge may need to be replaced more often if 
you are using very hard water. Replace the cartridge when you notice an increase in white 
dust build-up.  If white dust still forms around the humidifier after a new cartridge has been 
installed, consider using distilled water. To purchase new demineralization cartridges, model 
# UHE-HDC4, go back to the retailer (where you purchased your humidifier), or 
visit www.homedics.com

If you live in an area with hard water, or use a water softener, we recommend using 
distilled water for better results from your humidifier. Never use water softening 
additives in your humidifier.

Installation Instructions

1. Remove demineralization cartridge from packaging and let it soak  

in water for 10 minutes.

2. Remove the tank from humidifier base and turn it over.
3. Unscrew the tank cap by turning the cap counter-clockwise.
4. Fill the tank with water as shown in the How to Fill section of the instructions included  

with your humidifier.

5. Add the soaked demineralization cartridge into the tank.
6. Replace the tank cap by turning clockwise.
7. Place the tank back on the base.

Demineralization Cartridge

Fig. 7

Fig. 8

TIMER

+

HUMIDISTAT

MIST

WARM

LAMP

TIMER

+

HUMIDISTAT

MIST

WARM

LAMP

TIMER

+

HUMIDISTAT

MIST

WARM

LAMP

TIMER

+

HUMIDISTAT

MIST

WARM

LAMP

Summary of Contents for UHE-WM68

Page 1: ...du contrôle de HoMedics Cette garantie est valide uniquement si le produit a été acheté et utilisé au pays dans lequel le produit a été acheté La garantie ne couvre ni un produit nécessitant des modifications ou une adaptation afin qu il puisse fonctionner dans un pays autre que le pays pour lequel le produit a été conçu fabriqué approuvé ou autorisé ni la réparation d un produit endommagé par ces...

Page 2: ...NEVER use the humidifier in an environment where explosive gases are present DO NOT place the humidifier near heat sources such as a stove and do not expose the humidifier to direct sunlight DO NOT carry this unit by the power cord or use the power cord as a handle To disconnect turn all controls to the off position then remove the plug from the outlet DO NOT use outdoors For indoor use only SAVE ...

Page 3: ...tion When the tank is empty the unit will shut off automatically Capacity 1 4 gallon 5 29 liters Run Time 65 hours Run time is calculated based on using cool water and setting the mist level to low setting Based on the natural humidity level in your home the temperature of water you use and the mist level setting you choose you may experience longer or shorter run times FIG 1 TIMER HUMIDISTAT MIST...

Page 4: ...TAT button The humidity level will decrease on the LCD display by 5 Keep pressing the HUMIDISTAT button until the desired humidity level setting is reached NOTE To eliminate any programmed Humidistat setting press either or until you reach CO level One level above 70 or one level below 35 NOTE When the set humidity level is reached the humidifier will CYCLE OFF until the humidity in the room drops...

Page 5: ... in the humidifier It is caused only by minerals suspended in the water How and Why To Use Demineralization Cartridges The HoMedics demineralization cartridge will help reduce the potential for white dust a deposit of minerals left behind from using hard water in your humidifier The cartridge should be replaced every 30 40 fillings The cartridge may need to be replaced more often if you are using ...

Page 6: ...ive Noise Unit is not level Low water level Place unit on a flat even surface Check the water level Refill the tank if the water is low White Dust Accumulation Hard water used Demineralization Cartridge needs replacement Use distilled water and a Demineralization Cartridge Replace Demineralization Cartridge Troubleshooting FCC DISCLAIMER NOTE This product has been tested and complies with the requ...

Page 7: ...od the product is at a repair facility or otherwise awaiting parts or repair or any other conditions whatsoever that are beyond the control of HoMedics This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it w...

Page 8: ...se el suministro eléctrico Siempre sostenga el tanque de agua firmemente con ambas manos al llevar un tanque de agua lleno NUNCA use el humidificador en un ambiente en el que haya gases explosivos NO coloque el humidificador cerca de fuentes de calor como una estufa y no exponga el humidificador a la luz solar directa NO lleve esta unidad tomándola del cable ni use el cable como manija Para descon...

Page 9: ... conveniencia Protección de apagado automático Cuando el tanque esté vacío la unidad se apagará automáticamente Capacidad 1 4 galones 5 29 litros Tiempo de funcionamiento 65 horas El tiempo de funcionamiento se calcula basándose en el uso agua fría y fijando el nivel de niebla en bajo Según el nivel de humedad natural de la casa la temperatura del agua que use y el nivel de niebla que elija es pos...

Page 10: ...medad hasta alcanzar el nivel de humedad deseado La pantalla LCD mostrará el nivel de humedad conjunto durante 3 segundos a continuación se mostrará la humedad actual Para disminuir el valor de nivel de humedad presione el botón HUMIDISTAT disminución de humedad El nivel de humedad disminuirá en la pantalla LCD de a 5 Mantenga presionado el botón HUMIDISTAT DECREASE disminución de la humedad hasta...

Page 11: ...e su humidificador Nunca use aditivos para ablandar el agua en su humidificador Instrucciones de instalación 1 Retire el cartucho de desmineralización del envase y remójelo en agua durante 10 minutos 2 Retire el tanque de la base del humidificador y voltéela 3 Desenrosque la tapa del tanque girando la tapa hacia la izquierda 4 Llene el tanque con agua como se muestra en la sección Cómo llenar de l...

Page 12: ...agua limpia Fig 7 Para eliminar sarro o acumulación de desechos use una mezcla de vinagre y agua tibia en partes iguales para limpiar el interior del tanque Sugerencia limpie el tanque de agua una vez cada dos o tres semanas según las condiciones del agua Para limpiar la membrana ultrasónica Vierta una mezcla de partes iguales de vinagre y agua sobre la superficie de la membrana ultrasónica y deje...

Page 13: ...l país en que se compra Un producto que requiera modificaciones o adaptación para habilitar su funcionamiento en cualquier otro país que no sea aquel para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no está cubierto en esta garantía LA GARANTÍA QUE SE PROPORCIONA EN EL PRESENTE DOCUMENTO SERÁ LA GARANTÍA ÚNICA Y EXCLUSIVA NO E...

Page 14: ...rosol ou de l oxygène ont été utilisés L appareil doit être débranché de la prise de courant avant de commencer le nettoyage Lorsque le réservoir d eau est plein et que vous désirez le manipuler veuillez le tenir fermement avec les deux mains N UTILISEZ JAMAIS l humidificateur en présence de gaz explosifs NE PLACEZ PAS l humidificateur près d une source de chaleur par exemple un poêle et ne l expo...

Page 15: ...ammable jusqu à 24 heures Veilleuse Lumière d affichage Une fonction d éclairage de nuit est également incluse pour votre commodité Arrêt automatique de protection Lorsque le réservoir est vide l appareil s éteint automatiquement Capacité 1 4 gallon 5 29 litres Autonomie 65 heures L autonomie est calculée selon l utilisation d une eau froide et d un réglage d émission de vapeur au niveau faible Se...

Page 16: ...outon HUMIDISTAT autant de fois que nécessaire pour atteindre le taux d humidité souhaité L écran ACL affiche le taux d humidité programmé pendant 3 secondes et ensuite affiche le taux d humidité actuel Pour diminuer le taux d humidité programmé appuyez sur le bouton HUMIDISTAT Le taux d humidité programmé diminuera de 5 comme vous pourrez le voir à l écran ACL Appuyez sur le bouton HUMIDISTAT aut...

Page 17: ...ucisseur d eau dans votre humidificateur Instructions d installation 1 Enlevez la cartouche de déminéralisation de son emballage et trempez la dans de l eau pendant 10 minutes 2 Retirez le réservoir de la base de l humidificateur et retournez le 3 Dévissez le bouchon du réservoir en le tournant dans le sens antihoraire 4 Remplissez le réservoir avec de l eau en suivant les instructions de la secti...

Page 18: ... et rincez l intérieur du réservoir avec de l eau propre Fig 7 Pour enlever le tartre ou les dépôts nettoyez l intérieur du réservoir avec un mélange 50 50 d eau tiède et de vinaigre Suggestion nettoyez le réservoir d eau toutes les deux ou trois semaines selon la qualité de l eau Nettoyage de la membrane ultrasonique Versez un mélange 50 50 d eau et de vinaigre sur la surface de la membrane ultra...