Homa H76 K Original Instruction Manual Download Page 17

EngliSH | 17

Caution

Never operate the machine if the safety and monitor-

ing devices have been removed or damage, or if they 

do not work.

2.8. Pumped fluids 

Each pumped fluid differs in regard to composition, cor-
rosiveness, abrasiveness, TS content and many other 
aspects. Generally, our products can be used for many 
applications. For more precise details, see chapter 3, the 
machine data sheet and the order confirmation. It should 
be remembered that if the density, viscosity or the gener-
al composition change, this can also alter many parame-
ters of the product.

Different materials and impeller shapes are required for 
different pumped fluids. The more exact your specifica-
tions on your order, the more exactly we can modify our 
product to meet your requirements. If the area of applica-
tion and/or the pumped fluid change, we will be happy to 
offer supportive advice.

When switching the product into another pumped fluid, 
observe the following points:

• 

Products which have been operated in sewage or 
waste water must be thoroughly cleaned with pure 
water or drinking water before use.

• 

Products which have pumped fluids which are haz-
ardous to health must always be decontaminated 
before changing to a new fluid. Also clarify whether 
the product may be used in a different pumped fluid.

• 

With products which have been operated with a lu-
bricant or cooling fluid (such as oil), this can escape 
into the pumped fluid if the mechanical shaft seal is 
defective.

Danger - explosive fluids!

It is absolutely prohibited to pump explosive liquids 

(e.g. gasoline, kerosene, etc.). The products are not 

designed for these liquids!

2.9. Sound Pressure

Depending on the size and power (kW), the pump has 
a sound pressure of about 40dB (A) to 70dB (A) during 
operation. However, the actual sound pressure depends 
on several factors. These are, for example, the type of 
installation and set-up, mounting of accessories, piping, 
operating point, immersion depth, and much more.

3. General description

3.1. Application

Compact automatic pump designed to remove conden-
sate water from furnace burners, gas or oil condensing 
boilers, air conditioners, refrigeration display cabinets and 
de-humidifiers where drainage by gravity is not possible.

Attention: Regulations of water authorities or other relevant au-

thorities must be obeyed when condensate is being disposed of. 

Condensate from condensing boilers being operated with stan-

dard heating-oil (not low on sulphur) may not be disposed of into 

the canalization without being neutralized. This is also true for 

condensing boiler systems exceeding 200 kW.

Maximum liquid temperature should be 50°C.

3.2. Types of use

The condensate pump is designed for intermittent oper-
ation.

3.3. Construction

The condensate pump H76K consists of a collection tank 
with a single phase motor and an integrated float switch, 
3 inlets and pressure side connection with integrated back 
water valve. An additional float switch activates a safety 
switch with optional closing or opening contacts. A device 
for wall mounting, 1.8 m of cable and 6 m of discharge 
hose are also included.

3.3.1. Technical data

Discharge

9,5 mm (3/8“), sleeve with back water 
valve

Voltage

230V / 1Ph, 50Hz

Motor power

75 kW

Nominal current

0,6 A

Speed

2900 rpm

Degree of protection

IP44

Standard cable length

1,8 m

max. head

5,3 m

max. flow

5 l/min

max. liquid temperature

50°C

Weight

2,8 kg

3.3.2. Control devices

Automatic float switch

Version with automatic float switch and potential free 
alarm contact.

Summary of Contents for H76 K

Page 1: ...Original Betriebsanleitung EN Original Instruction Manual FR Manuel d instructions original NL Originele handleiding H76 K...

Page 2: ...ienpersonal 06 2 5 Elektrische Arbeiten 06 2 6 Verhalten w hrend des Betriebs 07 2 7 Sicherheits und berwachungseinrichtungen 07 2 8 F rdermedien 07 2 9 Schalldruck 07 3 Allgemeine Beschreibung 08 3 1...

Page 3: ...setzt werden gem aktuellster HOP SEL Variante Wir haben die angebotene Pumpe an hand der uns zur Verf gung stehenden Daten ausgew hlt Bitte beachten Sie dass die angebotenen Pumpen nur im dargestellte...

Page 4: ...se Vereinbarungen laufen mindes tens bis zum vereinbarten Ende der Gew hrleistungszeit des Produktes 1 5 2 Ersatzteile An und Umbauten Es d rfen nur Originalersatzteile des Herstellers f r Reparatur A...

Page 5: ...s die Oberfl chen des Produktes sehr hei werden Betriebsart S1 Dauerbetrieb Unter Nennlast wird eine gleichbleibende Temperatur er reicht die auch bei l ngerem Betrieb nicht mehr ansteigt Das Betriebs...

Page 6: ...llstand gekommen sein Der Bediener hat jede auftretende St rung oder Unregelm igkeit sofort seinem Ver antwortlichen zu melden Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich...

Page 7: ...efe uvm Gefahr durch elektrischen Strom Durch unsachgem en Umgang mit Strom bei elek trischen Arbeiten droht Lebensgefahr Diese Arbei ten d rfen nur vom qualifizierten Elektrofachmann durchgef hrt wer...

Page 8: ...rrichtung zur Wandaufh n gung 1 8 m Anschlusskabel sowie 6 m Druckschlauch geh ren ebenfalls zum Lieferumfang 3 3 1 Technische Daten Druckanschluss 9 5 mm 3 8 T lle mit R ckschlagventil Spannung 230V...

Page 9: ...um n chsten vorhandenen Anschluss und schlie en ihn dort an Der Druckschlauch sollte von der Kondensatpumpe aus ge sehen zun chst steigend dann stetig leicht fallend und knickfrei verlegt werden Zur S...

Page 10: ...en Wasser eingeleitet Nach einer F llmenge von ca 1 5 l startet die Anlage auto matisch und f rdert das Wasser in die Kanalisation 7 St rungssuche und behebung Um Sach und Personensch den bei der Bese...

Page 11: ...DEUTSCH 11 Notizen Notes...

Page 12: ...2 5 Electrical work 16 2 6 Operating procedure 16 2 7 Safety and control devices 16 2 8 Pumped fluids 17 2 9 Sound Pressure 17 3 General description 17 3 1 Application 17 3 2 Types of use 17 3 3 Cons...

Page 13: ...the offered pumps may only be used in the defined field of application Operating the pump out side the range of application can lead to operational prob lems or significant damage to the unit Particul...

Page 14: ...original spare parts can seriously damage the product and or injure personnel 1 5 3 Maintenance The prescribed maintenance and inspection work should be carried out regularly This work may only be car...

Page 15: ...d technical information Furthermore every other chapter contains specific safety instructions and techni cal information All instructions and information must be observed and followed during the vario...

Page 16: ...sult in fatal injury This work may only be carried out by a qualified electrician Beware of damp Moisture penetrating cables can damage them and render them useless Furthermore water can pen etrate in...

Page 17: ...ending on the size and power kW the pump has a sound pressure of about 40dB A to 70dB A during operation However the actual sound pressure depends on several factors These are for example the type of...

Page 18: ...to the next available connection The pressure hose should be installed rising then falling steadily and has to be free of breaks To stabilize the pres sure hose a fixed cable tube can be used Level co...

Page 19: ...h and the bottom part of the pump body as well as the tank bottom part are freely accessible These parts can now be washed with warm water and mild soap After cleaning place the upper part on the low...

Page 20: ...vaux lectriques 24 2 6 Comportement pendant l exploitation 25 2 7 Dispositifs de s curit et de surveillance 25 2 8 Agents pomper 25 2 9 Pression acoustique 25 3 Description g n rale 26 3 1 Utilisation...

Page 21: ...cifions et ceci tout moment selon la version HOP SEL actuelle Nous avons s lectionn la pompe sur la base des don n es dont nous disposons A noter que les pompes of fertes peuvent uniquement tre utili...

Page 22: ...riode de garantie du pro duit 1 5 2 Pi ces de rechange ajouts et transformations Seules des pi ces de rechange originales du fabricant peuvent tre utilis es pour la r paration le remplace ment ainsi q...

Page 23: ...une temp rature constante qui ne peut plus augmenter m me en cas de fonctionnement prolong est atteinte Le mat riel peut fonctionner sans pause sous charge nominale sans que la temp rature ad missibl...

Page 24: ...eau lectrique et s curis contre une remise en marche Toutes les pi ces rotatives doivent tre im mobilis es L op rateur doit communiquer imm diatement l ap parition de toute d faillance ou irr gularit...

Page 25: ...t et de surveillance Ces dispositifs ne peuvent pas tre d mont s ou d branch s Les dispositifs doivent tre raccord s avant la mise en service par un lectricien et leur fonctionnement correct doit tre...

Page 26: ...potentiel Un dispositif pour suspension murale un c ble de raccordement de 1 8 m ainsi qu un tuyau de pression de 6 m font aussi partie de la fourniture 3 3 1 Caract ristiques techniques Raccord pour...

Page 27: ...s montant puis ensuite l g rement tom bant et sans flambage Pour la stabilisation du tuyau de pression un tuyau rigide de protection du c ble peut tre utilis Commande de niveau Outre le c ble r seau l...

Page 28: ...a directive 91 689 CEE Seuls les lubrifiants recommand s par le fabricant peuvent tre utilis s Les huiles et les lubrifiants ne peuvent pas tre m lang s Utilisez uniquement des pi ces originales du fa...

Page 29: ...d marre pas Pas de tension V rifier l alimentation en tension Fiche m le non ins r e Ins rer la fiche m le Pompe bloqu e par des boues ou des solides Nettoyer le r cipient et le corps de pompe Moteur...

Page 30: ...soneel 34 2 5 Elektrische werkzaamheden 34 2 6 Gedrag tijdens het bedrijf 35 2 7 Veiligheids en bewakingscontroles 35 2 8 Vloeistoffen 35 2 9 Geluidsdruk 35 3 Algemene beschrijving 36 3 1 Toepassing 3...

Page 31: ...worden toegepast volgens de meest re cente HOP SEL variant Wij hebben de aangeboden pomp geselecteerd aan de hand van de ons ter beschikking staande gegevens Houd er rekening mee dat de pompen in de...

Page 32: ...afspraken lopen ten minste tot aan het overeengekomen einde van de wettelijke garan tietermijn van het product 1 5 2 Onderdelen aan en ombouwwerkzaamheden Er mogen uitsluitend originele onderdelen va...

Page 33: ...wordt een gelijkblijvende tem peratuur bereikt die ook bij langer bedrijf niet meer stijgt Het materieel kan ononderbroken onder nominale belas ting werken zonder dat de toegestane temperatuur wordt...

Page 34: ...nggevende Een onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder vallen Falen van de veiligheids en of bewa...

Page 35: ...inrichtingen mogen niet worden gedemonteerd of uitgeschakeld Inrichtingen moeten v r de inbedrijfstelling door een elektricien aan gesloten en op correcte werking gecontroleerd zijn Houd er hiervoor...

Page 36: ...akcontacten Een systeem voor wandophanging 1 8 m aansluitkabel en 6 m drukslang behoren eveneens tot de leveringsomvang 3 3 1 Technische gegevens Persaansluiting 9 5 mm 3 8 tule met terugs lagklep Spa...

Page 37: ...oleer of het systeem lekvrij is De correcte werking van de pomp en de levensduur van de slijtdelen is voor een belangrijk deel afhankelijk van een regelmatige controle en onderhoud van de installatie...

Page 38: ...en Microschakelaar defect Vervanging door vakper soneel Verdere stappen voor de probleemoplossing Wanneer de hier vermelde punten niet helpen de storing te verhelpen neem dan contact op met de klanten...

Page 39: ...halter zur Funktionskontrolle Zulauf Blindkappe Anschlusst lle 3 8 mit integriertem Kugel R ckflussverhinderer f r PVC Schlauch I 9 Anschlusskabel mit Netzstecker Schwimmerschalter mit potentialfreiem...

Page 40: ...ber pads Test switch for fuction control Inlet covered with caps Pressure side connection 3 8 with integrated non return valve for PVC hose I 9 Cable with plug Float switch with volt free alarm contac...

Page 41: ...tement en caoutchouc Interrupteur test pour contr le des fonctions Entr e bouchon aveugle Raccord 3 8 avec clapet boule anti retour pour tuyau PVC I dia 9 c ble d alimentation avec prise flotteur avec...

Page 42: ...e rubber buffer Testschakelaar voor functiecontrole toevoer blinddop Ansluittule 3 8 met ge ntegreerde balkeerklep voor PVC slang I 9 Aansluitkabel met netstekker Vlottenschakelaar met potentiaal vrij...

Page 43: ...edingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonst...

Page 44: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bi...

Page 45: ...i res corrosives non oui substance mati res micro biologiques non oui substance mati res explosives non oui substance mati res radioactives non oui substance autres substances non oui substance D clar...

Page 46: ...tourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioa...

Page 47: ...ed the equipment or manufacturer of the equipment Avis DEEE La directive sur les d chets d quipements lectriques et lectroniques DEEE qui est devenue applicable comme loi europ enne le 13 f vrier 2003...

Page 48: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Reviews: