background image

Description of the device

SAA 902 | Version 1.03

9

4

Description of the device

4.1 Machine

Figures in this operation manual serve to provide a 
basic under-standing and may differ from the actual 
design.

Fig. 2: Chip extraction unit SAA 902

  1 Dust bag hook
  2 Dust bag
  3 Quick release dust bag
  4 Transport handle
  5 Quick-release device catch bag
  6 Catch bag
  7 Base plate
  8 Chassis
  9 Suction hose
10 Wheel
11 Stabilizing sheet
12 Plastic housing
13 Holes for dust bag hooks
14 ON / OFF switch
15 Engine

4.2 Scope of supply

- 1 chip bag and 1 filter sack

- 2 hose clips and 2 straps

- Hose adapter set 4-part

- 2000 mm PU hose Ø 100 mm

5

Technical Data

5.1 Table

5.2 Type plate

Fig. 3: Type plate SAA 902

5.3 Accessories

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Model

SAA 902 

Length

900 mm

Width

500 mm

Height

1550 mm

Weight

19 kg

Supply voltage

230 V

Rated volume flow

1200 m³/h

Negative pressure max.

1100 Pa

Extraction duct inlet outside 
nominal width

100 mm

Extraction duct outlet outside 
nominal width Electrical data

100 mm

Input power

0,55 kW

Output power

0,35 kW

Sound power level max.

94,9 dB(A)

Sound pressure level max.

80,2 dB(A)

Tips and recommendations

We recommend to use only high quality original Holz-
star accessories. Only with original accessories, a 
flawless operation and optimal work results can be 
guaranteed.

Description

Item number

Filter bag SAA 902

5930903

Chip bag SAA 902

(1 pack of 10 pieces)

5930904

Adapter set for SAA 902

5930905

Reducing socket, not flanged, Ø 
100 mm wide, 60 mm narrow

5142427

Floor cleaning set BRS 1

5148100

Summary of Contents for 5923902

Page 1: ...Instruction Manual Chip extraction unit SAA 902 SAA 902 ...

Page 2: ...General safety aspects 6 2 7 Safety measures when dealing with electricity 7 2 8 Safety measures for the use of tools 7 2 9 Safety measures for processing 7 2 10 Safety measures during maintenance and servicing 8 2 11 Safety check 8 3 Intended Use 8 3 1 Residual risks 8 4 Description of the device 9 4 1 Machine 9 4 2 Scope of supply 9 5 Technical Data 9 5 1 Table 9 5 2 Type plate 9 5 3 Accessories...

Page 3: ...se submit any information and experiences you make during application of the machine as these may be valuable for product improvements 1 3 Disclaimer All data in this operation manual has been compiled on the basis of the state of the art valid standards and gui delines as well as our many years of expertise and ex perience The manufacturer shall not be liable for damage in the following cases Fai...

Page 4: ...aff with the required pro tective equipment and wearing the required pro tective equipment shall be mandatory Operators shall also be responsible for maintaining the machine in a technically perfect condition For this rea son the following shall apply Operators shall make sure that the maintenance in tervals described in these operating instructions are complied with Operators shall regularly chec...

Page 5: ...at work Staff must wear the personal protective equipment indicated in individual sections of these operating instructions when carrying out the different tasks on the machine The personal protective equipment is described in the following section 2 5 Safety labels on the Chip extrac tion unit The following safety labels and instructions are attached to the Chip Extraction Unit s Fig 1 and must be...

Page 6: ...n and concentration Do not use the extraction system if you are not concentrated Operation or maintenance of the extraction system is prohibited for persons under the age of 18 or un der the influence of alcohol drugs or medication Defective or damaged parts in the device must be replaced immediately Keep children away from the machine Only operate the machine with fully and correctly installed sa...

Page 7: ... not use the machine for purposes for which it is not intended 2 Do not overload the extraction system She works bet ter and safer in the specified performance range Do not use the extraction system for heavy work requiring a more powerful machine 3 Check the stability of the machine 4 Note that using tools other than those recommended by the manufacturer and other accessories may result in injury...

Page 8: ... intended Non industrial use is given when no employee no persons in the vocational training as well as in schools uses the exhaust system There is no liability for damages due to improper use The extraction system has not been designed for com mercial craft or industrial use For structural and technical changes to the chip extraction unit the company Stürmer Maschinen GmbH assumes no liability Cl...

Page 9: ...ig 3 Type plate SAA 902 5 3 Accessories 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Model SAA 902 Length 900 mm Width 500 mm Height 1550 mm Weight 19 kg Supply voltage 230 V Rated volume flow 1200 m h Negative pressure max 1100 Pa Extraction duct inlet outside nominal width 100 mm Extraction duct outlet outside nominal width Electrical data 100 mm Input power 0 55 kW Output power 0 35 kW Sound power level...

Page 10: ...le for recycling and must always be disposed of using material based recycling systems Packaging materials made of cardboard must be shred ded and recycled as waste paper The foils are made of polyethylene PE padding is made of polystyrene PS Dispose of these substances at a recycling centre or hand them over to a qualified wa ste disposal company 6 3 Storage The chip extraction unit must be thoro...

Page 11: ...ides of the chassis together with the M5x16 cheese head screws and M5 hex nut Fig 6 Fig 6 Mounting device unit Step 5 Insert a hose fitting 17 over the suction hose 7 as far as it will go to the suction connection of the device and fix it with the hose clamp accor ding to fig 7 Fig 7 Hose fitting Step 6 Pull the chip bag 6 over the lower opening of the plastic housing 13 so that it completely clos...

Page 12: ...ystem insert a hose attachment A over the suction hose 11 Now insert the connection adapter 18 as far as it will go into the suction hose 11 and secure it by tightening the sluice attachment A Fig 11 Connection adapter 6 7 Setting up the chip extraction unit Place the machine on a stable level surface The distance to the wall should be at least 800 mm Check your electrical connection voltage This ...

Page 13: ...rounded to dissipate any electrostatic energy 7 Operation 7 1 Switch on Check that the suction hose is firmly connected to the extraction unit and to the extraction adapter of the woodworking machine Check if the chip bags are well fastened Switch on the extraction system by pressing the green button I Turn on the woodworking machine 7 2 Switch off Switch off the woodworking machine Exhaust system...

Page 14: ...ips and recommendations The Chip Extraction Unit is constructed for efficient operating To guarantee a long life the servicing aspects are to be carried out regularly DANGER Danger to life due to electrical shock Danger of live through electric shock by contact with live power components The Chip Extraction Unit may connected only from Qualified electrician Repairs on the electrical system must ex...

Page 15: ...ted as normal household waste but must be returned to a collection point for the recycling of electrical and electronic equipment By helping to properly dispose of this product you are protecting the environment and the health of others Environment and health are endan gered by improper disposal Material recycling helps to re duce the consumption of raw materials For more informa tion about recycl...

Page 16: ...plate attached to the device Example The engine for the Chip extraction unit SAA 902 must be ordered The engine has the number 11 in the spare parts drawing 1 By ordering spare parts send a copy of the spare parts drawing 1 with the marked part engine and marked positon number 11 to the dealer or spare parts depart ment and provide the following information Type of device Chip extraction unit SAA ...

Page 17: ...03 17 11 2Spare parts drawing The following drawing are intended to help identify the necessary spare parts To order please send a copy of the part drawing with the marked components to your dealer Fig 13 Spare parts drawing SAA 902 ...

Page 18: ...18 SAA 902 Version 1 03 Electrical schematic 12 Electrical schematic Fig 14 Wiring Diagram SAA 902 ...

Page 19: ... 69 2012 Household and similar electrical appliances Safety Part 2 69 Particular requirements for wet and dry vacuum cleaners including power brush for commercial use DIN EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure DIN EN 55014 1 2017 Electromagnetic compatibility Requirements for household appliances elec...

Page 20: ...www holzstar de ...

Reviews: