USR Register
The USR register is the status register for the UART, which can be read by the program to
determine the present status of the UART. All flags within the USR register are read only and further
explanations are given below.
Bit
7
6
5
4
3
2
1
0
Name
PERR
NF
FERR
OERR
RIDLE
RXIF
TIDLE
TXIF
R/W
R
R
R
R
R
R
R
R
POR
0
0
0
0
1
0
1
1
Bit 7
PERR
: Parity error flag
0: No parity error is detected
1: Parity error is detected
The PERR flag is the parity error flag. When this read only flag is “0”, it indicates a
parity error has not been detected. When the flag is “1”, it indicates that the parity of
the received word is incorrect. This error flag is applicable only if Parity mode (odd or
even) is selected. The flag can also be cleared by a software sequence which involves
a read to the status register USR followed by an access to the RXR data register.
Bit 6
NF
: Noise flag
0: No noise is detected
1: Noise is detected
The NF flag is the noise flag. When this read only flag is “0”, it indicates no noise
condition. When the flag is “1”, it indicates that the UART has detected noise on the
receiver input. The NF flag is set during the same cycle as the RXIF flag but will not
be set in the case of as overrun. The NF flag can be cleared by a software sequence
which will involve a read to the status register USR followed by an access to the RXR
data register.
Bit 5
FERR
: Framing error flag
0: No framing error is detected
1: Framing error is detected
The FERR flag is the framing error flag. When this read only flag is “0”, it indicates
that there is no framing error. When the flag is “1”, it indicates that a framing error
has been detected for the current character. The flag can also be cleared by a software
sequence which will involve a read to the status register USR followed by an access to
the RXR data register.
Bit 4
OERR
: Overrun error flag
0: No overrun error is detected
1: Overrun error is detected
The OERR flag is the overrun error flag which indicates when the receiver buffer has
overflowed. When this read only flag is “0”, it indicates that there is no overrun error.
When the flag is “1”, it indicates that an overrun error occurs which will inhibit further
transfers to the RXR receive data register. The flag is cleared by a software sequence,
which is a read to the status register USR followed by an access to the RXR data
register.