Holman iWeather WS5029 Instruction Manual Download Page 13

11

Once the sensor unit is installed it is important to set the main internal receiver unit.

There is a lot of information shown on this display unit and most of the measurements can be 
displayed in more than one measurement standard.

For example the clock can operate in 12 hour AM & PM mode or in a 24 hour military style.

The rainfall can be in millimetres (mm) or in inches (in). The choice of how you run the 
measurements is yours.

To set all the parameters you must work your way logically through the measurements.

The numbers and settings are controlled by six setting keys on the top & back of the main unit. 
These are labelled MODE , 

+

-

ALARMALERT & SNOOZE / LIGHT.

After inserting the batteries the main unit will connect with the outdoor sensor by wireless signal.

The 2 units must be properly “synchronised”. This should have been done during assembly. If 
not, the process take about 3 minutes to do. It is done automatically by both units providing both 
sets of batteries are installed within 3 minutes of each other. You will know when the connection 
has been made once the outside measurements are displayed on the main unit.

If a wireless connection is not made you can start the “sync” process by holding down the 
“ALARM” button for more than 3 seconds.

1) Introduction

2) Initial Operation

Programming the Internal Main Unit

Summary of Contents for iWeather WS5029

Page 1: ...anual Product Code WS5029 For more information regarding this product and to watch the video of how it works please scan the QR code with your mobile device Professional Weather Station with Wireless...

Page 2: ...reless Connection 7 Barometer Information 9 Installation of the Weather Vane 10 Programming the Internal Main Unit 1 Introduction 11 2 Initial Operation 11 3 Initial Adjustments 12 4 Setting the Time...

Page 3: ...rainy storm Barometer and bar and data of 12 hours history for air pressure Indoor outdoor temperature and humidity with trend Max min of temperature and humidity Thermometer measuring range inside C...

Page 4: ...l alarm 14 Time 15 RCC symbol not applicable in Australia 16 Summer time not applicable in Australia 17 Outdoor low battery 18 Outdoor humidity 19 Outdoor humidity trend 20 Indoor humidity 21 Outdoor...

Page 5: ...Cable from wind speed sensor insert into the socket of wind direction sensor 2 Cable from wind direction and cable from rain sensors to the corresponding sockets of the thermo hygro sensor by clickin...

Page 6: ...only fit in one position When you find the correct position it fits snugly on and then rotate it clockwise to secure the cover in place It is important that the cover is securely located The following...

Page 7: ...be in clear air Once orientation is good make sure all the bolts and nuts are secure Assembling The Sensor Unit 5 5 Mount the Thermo Hygro Sensor to the plastic bracket labelled 3 in illustration oppo...

Page 8: ...speed direction shows on the main unit If this does not happen then press the ALARM button for more than 3 seconds and the units will re establish their wireless connection If this still fails to con...

Page 9: ...on the internal receiver does not show the batteries are low Low batteries can cause the wireless connection to fail 2 Make sure the red LED on the outside thermometer hygrometer is flashing about onc...

Page 10: ...proximately 3 minutes See Picture 3 iii While this is flashing insert within 3 minutes the batteries into the external thermomter hygrometer shown in picture 1 The LED light will flash when the unit i...

Page 11: ...he symbol will flash for 3 minutes and re connection should be achieved Barometer Information The barometric pressure is affected by 2 factors i The Local conditions in the atmosphere A local storm wi...

Page 12: ...line of the house or shed 3 A very effective way of fixing to a vent pipe is to use 3 or 4 cable ties that can secure the stainless steel pole in place ensuring the sensors are located above the vent...

Page 13: ...six setting keys on the top back of the main unit These are labelled MODE ALARM ALERT SNOOZE LIGHT After inserting the batteries the main unit will connect with the outdoor sensor by wireless signal...

Page 14: ...reading is accurate This is because the barometric pressure decreases with altitude Once adjusted push the Snooze Light f button Next you will see the weather forecast i flash By using the or key you...

Page 15: ...confirm Next the display for the month will flash Use or to select the month then press MODE to confirm Next the display for the date will flash Use or to select the date then press MODE to confirm N...

Page 16: ...showing 2nd press ALARM to cancel the alarm 1 then activate the alarm 2 with alarm symbol showing 3rd press ALARM to activate the alarm 1 and alarm 2 with alarm symbol showing 4th press ALARM to cance...

Page 17: ...lower limit of inside temperature will flash use or to set the minimum alert temperature Next press ALERT and the upper limit of outside temperature will flash use or to set the maximum alert temperat...

Page 18: ...manual set up to select mph kmh the display of the speed is updated approximately every minute Wind direction There are 16 wind directions the display of the direction is updated approximately every m...

Page 19: ...the ALARM button for 3 seconds to search for the outdoor sensor the RF signal symbol at the outside area will flash when trying to connect RF reception is weaker in rooms with concrete walls e g in t...

Page 20: ...y from the original date of purchase To claim warranty the product must be returned with a copy of the original receipt We will honour all statutory guarantees that this product is of acceptable quali...