103
Troubleshooting
VAcUUM SYSTEM PROBLEMS
Vacuum Loss or Failure:
•
Vacuum blower is not engaged - activate OMSI PTO to activate vacuum system
• Vacuum RPM not high enough - adjust RPM higher
• Vacuum filter dirty & clogged - rinse with hose or replace if too badly clogged
• Worn or improperly adjusted shroud brush - adjust or replace brush
• Broken vacuum hose or fitting - inspect hoses & fittings and replace any parts damaged
• Vacuum line plugged with debris - remove clogged hose, flush to remove blockage or replace with
new hose if necessary
• Slipping or damaged vacuum belt - tighten belt or replace if worn badly
• Debris tank door leaking air or water - Compressor is not inflating seal - check compressor and
repair if necessary. Seal is dirty - clean seal. Seal is damaged - replace damaged seal.
• Debris tank 4” dump valve open - clear valve of any debris and close tightly; if valve still leaks, it
may be necessary to replace worn valve
• Relief valve stuck open - lubricate plate & stem and work it in and out to be sure it is free
• Vacuum filter canister door seal leaking - replace seal to eliminate vacuum leak
• Vacuum filter canister drain ball valve leaking or open - clean valve of any debris; if it is still
leaking, it may be necessary to replace worn valve
Relief valves stuck open & whistling:
• A blockage in vacuum hose between the tank and the Hog Head - locate and remove blockage
• Clogged vacuum filter - Clean or replace vacuum filter and clean canister tank bottom
• High water/debris level lifting shut-off ball in debris tank - Empty water from debris tank and dump
debris - clean shut-off ball to keep it from sticking shut, replace debris bag, clean door seal and close
Problem
Problem
Summary of Contents for Stripe Hog SH5000
Page 1: ...Operations Manual...
Page 2: ...2...
Page 4: ...4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 6: ...6 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 8: ...8 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 14: ...14 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 20: ...20 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 50: ...50 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 58: ...58 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 92: ...92 Component Repair THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 94: ...94 Component Repair...
Page 96: ...96 Component Repair...
Page 98: ...98 Component Repair...
Page 99: ...99 Fluid End Replacement Parts Appendix A Drawings and Supplies...
Page 100: ...100 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 104: ...104 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 106: ...106 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 110: ...110 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 118: ...118 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 121: ......