59
Section 4 - Maintenance
Step 4
Remove Swivel Tit Assembly/Gland Nut
While holding the thru-shaft with the 3/4” (19mm)
open end wrench through the slot in the motor
base, use a 15/16 (24mm) deep well socket or
box end wrench to remove the swivel tit gland nut
by turning it counterclockwise. Inspect the swivel
tit assembly and set it in a safe, clean location.
Figure 7 and 8.
Swivel Tit Assembly Gland Nut
Figure 7: Swivel Tit gland nut to be removed by turning counterclockwise with a 15/16” deep well socket or box end
wrench.
Figure 8: 3/4” (19 mm) open end wrench holding thru-
shaft and preventing it from turning while
removing swivel tit assembly/gland nut.