Loosen the screw on the bottom and unload the bottom (img.1).
Pass the power wire through the hole with gasket in the bottom. Connect the power wire into
connection-wire column according to the connection-wire diagram (img.2).
Fix the bottom with inflated screw on the selected position (img.1).
Install back the sensor on the bottom, tighten the screw and then test it.
Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise on the
maximum (sun) (img.4.)
Switch on the power; the sensor and its connected lamp will have no signal at the beginning.
After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal,
the lamp will turn on. While there is no another induction signal any more, the load should stop
working within 10sec±3sec and the lamp would turn off.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the
sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX
(darkness), the sensor would work. Under no induction signal condition, the sensor should stop
working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor
lamp could not work! If the lamp is more than 60W, the distance between lamp and sensor
should be 60cm at least.
INSTALLATION MANUAL
1
2
3
4
5
6
7
TECHNICAL SPECIFICATION
DETECTION RANGE:
360°
VOLTAGE:
220-240V/AC
FREQUENCY:
50/60Hz
RATED LOAD:
2000W (Incandescent lamp) 1000W (Energy-saving lamp & LED lamp)
DETECTION DISTANCE:
max. 20m (<24°)
TIME DELAY:
10sec ± 3sec to 30min ± 2min (adjustable)
AMBIENT LIGHT:
<3-2000LUX (adjustable)
INSTALLATION HEIGHT:
2.2-6m
4
| © Copyright 2020 Hoftronic
MANUAL OVERRIDE FUNCTION
1.
Sensor mode: Stay on
Now switch wall switch OFF-ON, OFF-ON twice within 3seconds. The sensor will now hold your light
ON continuously just likes a normal light.
2.
Stay on: Sensor mode(The following either method is ok)
1).
Switch your wall switch OFF, then switch ON after 0.3seconds.
2).
If the light left ON (not change the sensor to sensor mode by hand), the sensor itself will also auto-
matically return to the sensor mode after 8hours.