6.3 - AUTOMATIC GAUGES
6.3.1 - RIM DISTANCE GAUGE
- Pull out the distance gauge in position 0 and, keeping it quite still, press
- Move the distance gauge to position 15 and press
CORRECT CALIBRATION
- Return the gauge to rest position
- The wheel balancer is ready for operation
N.B.
: In the event of errors or faulty operation, the writing
: appears on the
display: shift the gauge to position 0 and repeat the calibration operation exactly as described above.
If the error persists, contact the Technical Service Department. In the event of incorrect input in the rim
distance gauge calibration function, press
to cancel it.
6.3.2 - DIAMETER GAUGE
- Currently preset diameter.
- Set the diameter with which to calibrate the machine (10 - 18")
- Press
- Move the gauge tip into measuring position (N.B. at 12 o' clock),
positioning it well as indicated in Fig. 5 - Pos. A and keeping it still, press
CORRECT CALIBRATION
- Return the gauge to rest position
- The wheel balancer is ready for operation
In the event of incorrect input in the diameter gauge calibration function, press
to cancel it.