5.4 - RESULT OF MEASUREMENT
Fig. 10
Inside correction
Outside correction
After performing a balancing spin, the amounts of unbalance are shown on the displays.
Displays with LED's 3- 4 lit up indicate the correct angular wheel position to mount the counterweights (12
o'clock position). When the acoustic beep is enabled (see section 4.6.1), acquisition of the dimensions is
accompanied by a "beep".
If the unbalance is less than the threshold selected,
is displayed instead of the unbalance. With
it is possible to read the values below the threshold chosen gram by gram.
5.4.1. - INDICATION OF EXACT CORRECTION POSITION IN ALU-M/ALU2/ALU3
In correction modes ALU-M/ALU2/ALU3 it is possible to cancel approximations in the mounting of the
counterweights by proceeding as follows:
1)
Press push button
N.B.: Correction position changes from 12 0'clock to 6 o'clock.
2)
Bring the wheel into correct angular position indicated by the instrument for each side.
3)
Pull out the gauge in Pos. B of fig. 5 bearing in mind that the following appears on the display:
indicating to move the gauge further to the outside
indicating to return the gauge to rest position
Fig. 11
The left display gives the indications for reaching the position used for the inside, while the right display
those for the outside.
4)
Apply the weights at 6 o'clock position for each side making reference to the gauge tip position.