6.2. - SELF-CALIBRATION
For machine self-calibration proceed as follows:
- Mount an
iron wheel of "average" size on the shaft, example: 6''x14'' (
±1'').
It does not have to be a perfectlybalanced wheel.
- Preset the exact dimensions of the wheel mounted.
- Perform a spin under normal conditions.
- Add 100 g (3.5 oz) on the outside in any position.
- Shift the 100 g. weight from the outside to the inside keeping the same
position.
- Turn the wheel with the 100 g. weight to the 12 o’clock position.
oppure
or
CAUTION!!
Presetting of incorrect dimensions would mean that the machine is not correctly calibrated,
therefore all subsequent measurements will be incorrect until a new self-calibration is
performed with the correct dimensions!
END OF SELF-CALIBRATION