Passenger Tire Changers Service Manual 07-13 Rev.B
80
Take a piece of paper and place it where the adjustment screw
should work on the cabinet. Tilt forward the
tower and pull the paper to verify if the end stroke screws are
touching the cabinet.
If one of the screws does not touch the cabinet, unlock the related counter nut and, using a screwdriver,
unscrew the screw until it will touch the cabinet.
Hold the screw and lock the counter nut.
Check again if both heads touch the support.
Mount the plastic protections.
Remove the air pressure reducer.
Connect the main air pressure.
Check if the machine works fine.
7.2 AUTOMATIC TOOL: CHECK – REPLACEMENT AND ADJUSTMENTS
:
1h
:
End key10,17 and 19mm, allen keys 3,5,6 and 8mm, rubber hammer, 13mm tube type key, rim of 17”.
:
Defective tool may cause the following malfunctions:
1.
Tool is broken.
TO CHECK THE TOOL:
Check if the tool is broken or mechanically damaged.
TO REPLACE THE TOOL:
Block the vertical rod with yellow button on the valve.
Disconnect the tool from the cylinder.