1.  Specification Sheet – Hoffman Purge/Pressurization Units 

 

Model No. (Example):  

       P CF B 1 YZ   

 (Note: Not all codes are applicable) 

 
Purge Unit Type 

=  

Purge/Pressurization Unit 

 

Purging Method 

CF =  

Continuous Flow 

 

 
 
 

Mounting Style 

B =  

Back Plate (Top/Side Mount) 316L 
Stainless Steel (NROB finish) 

F=  

Flush Mount (Side/Front Mount) 316L 
Stainless Steel (NROB finish) 

 
Size 

1 =  

Purge flow rate 8 scfm, 225 Nl / min 
 
 

 

 
 

 
 
 
Approvals / Certifications 

Y =  

 

 

Z = 

Europe 
EN 60079-0, EN 60079-2, 
EN 61241-0, EN 61241-4 
Sira 14ATEX1045X 
 
0518         II 2 (2) G D  

0518        II 3 (2) G D 

Ex [py] II T6 Gb  

 

Ex [pz Gc] IIC T6 Gb 

Ex [p] IIIC T85ºC Db  

Ex [p Dc] IIIC T85ºC 

Tamb -20ºC +55ºC   

Tamb -20ºC +55ºC 

 
IEC 
IEC 60079-0, IEC 60079-2, 
IEC 61241-4 
IECEx  SIR14.0019X 
 
Ex [py] II T6 Gb  

 

Ex [pz Gc] IIC T6 Gb 

Ex [p] IIIC T85ºC Db 

Ex [p Dc] IIIC T85ºC  

T

amb 

-20ºC +55ºC    

T

amb 

-20ºC +55ºC 

 
USA / Canada NFPA 496 
UL E466718 
Class I Div 1  

 

Class I Div 2 

Groups A, B, C & D  

Groups A, B, C & D

 
For limitations and conditions of use refer to the applicable certificate at the back of this manual. 

 
Supply Pressure 
:  

 

60 psi / 0.4MPa / 4 barg must be regulated at inlet. 
Maximum supply pressure 115 psi / 0.8MPa / 8 barg.  
Compressed Air / Nitrogen 
 

Flow & Pressure Sensors: 
One sensor for both  
“Low Pressure and Flow”    

1 "WC / 250 Pa ( 2.5 mbarg ) 

 
Spark Arrestor Unit:  
Purge / Dilution Flow Rate   

0.4 to 8 scfm / 10 to 225 Nl/min  
8 User selectable orifice plates 

Material   

 

 

Stainless Steel 

 
Relief Valve 
Opening Pressure:  

 

4” WC / 1 kPa (10 mbarg) 

Material:  

 

 

316L Stainless Steel, Spark Arrestor: Stainless Steel mesh, Neoprene Gasket 

 
Action on “Loss of Pressure”
:  

ALARM ONLY 

 
Alarm Switch (Signals)   

Zone 2 /Division 2 

 

 

 

 

“Alarm”: Dry, VFC, SPSTN/O Contact 

 

Hermetically Sealed Switch 

 

 

 

 

NI – Ex nA Non-incendive Circuits 

 

Ex m IIC T4 Gc 

 

 

 

 

V

max

 <254 V ac rms   

 

 

V

max

 =254 Vac rms 

 

 

 

 

I

max

 < 1 A   

 

 

 

I

max

 0.7 A 

 

 

 

 

 

Zone 1 or 2 / Division 1 or 2 

 

 

 

 

IS – Ex i circuits 

 

 

 

 

U

max

 = 30 Vdc 

 

 

 

 

I

max

 0.7 A 

Summary of Contents for PCFB1YZ

Page 1: ...ication Sheet CF Y Z Purge Pressurization Unit 2 Application Suitability 3 Installation Operation and Maintenance for CF Units Section 0 Description and Principle of Operation Section 1 Installation o...

Page 2: ...anada NFPA 496 UL E466718 Class I Div 1 Class I Div 2 Groups A B C D Groups A B C D For limitations and conditions of use refer to the applicable certificate at the back of this manual Supply Pressure...

Page 3: ...t be fitted to the Pressurized Enclosure The following materials are used in the construction of Hoffman Purge Pressurization Units If substances that will adversely affect any of these materials are...

Page 4: ...alibrated Outlet Orifices Where the Outlet Orifice disk is removable and can be easily changed by the user to give different flow rates according to the size of the PE and the available air supply cap...

Page 5: ...the PE Exception Power to Intrinsically Safe or other apparatus which is already suitable for the location need not be isolated by the Hoffman Purge Pressurization unit When utilizing Y Z Pressurizat...

Page 6: ...the RLV and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor with a spare Check the condition of the air supply filter element Clean or replace it as necessary 3...

Page 7: ...le cause 2 Excessive Pressurized Enclosure PE leakage Check around the PE when flow is taking place Any significant leakage must be cured Has a Leakage Test been done The total leakage should not exce...

Page 8: ...Arrestor with circle clip Fix Spark Arrestor to Enclosure ensuring that Control Unit and Spark Arrestor are diagonally opposed 5 Connect output dry contact alarm as required 6 Connect isolated air su...

Page 9: ...Quick Installation Guide PCFF1YZ...

Page 10: ...clip Fix Spark Arrestor to Enclosure ensuring that Control Unit and Spark Arrestor are diagonally opposed 5 Connect output dry contact alarm as required 6 Connect isolated air supply to Control Unit 7...

Page 11: ...Spark Arrestor Orifice Relief Valve Drawing...

Page 12: ...Relief Valve Position Relief Valve Cutout Schematic for both PCFB1YZ and PCFF1YZ...

Page 13: ...instructions and Article 504 of the NEC ANSI NFPA 70 3 For guidance on Installation see ANSI ISA RP12 6 Installation of IS Instrument Systems in Class I Hazardous Locations 4 Voc or Vt of associated a...

Page 14: ......

Page 15: ......

Page 16: ...Hoffman Enclosures Inc 2100 Hoffman Way Anoka Minnesota 55303 1745 USA Phone 763 422 2211 www hoffmanonline com P N 89108870 Dwg 89109562 A...

Page 17: ......

Reviews: