Modbus Communications 45
HIT-4G
HP-328
Fault Codes
The following table defines each bit for the fault codes returned when
polling register 7022 and 7023 using function code 03. When a value
of 1 is returned for a bit, it indicates that the fault has occurred since
last power on (7022) or is currently active (7023).
Bit
Fault
0
Reset, brownout
1
Reset, reset pin
2
Reset, DoBOR
3
Reset, wakeup from LPM5
4
Reset, security violation
5
Reset, supply voltage supervisor low
6
Reset, supply voltage supervisor high
7
Reset, supply voltage monitor low
8
Reset, supply voltage monitor high
9
Reset, DoPOR
10
Reset, watchdog timer timeout
11
Reset, watchdog timer key violation
12
Reset, flash key violation
13
Reset, PLL unlock
14
Reset, peripheral/configuration area fetch
15
Reset, power management key violation
16
Low battery
17
Pulse output overflow
18
Alarm, rate low
19
Alarm, rate high
20
Alarm, total
21
Flash segment 1 invalid
22
Flash segment 2 invalid
23
Maximum input frequency exceeded
24
EEPROM read error on startup
25
Code execution error
26
Flow rate exceeds 20mA setting
27
Temperature Input Fail
28
Pressure Input Fail
29
Flash Segments ZTable Invalid
30
Spare 2
31
Spare 1
Summary of Contents for HIT-4G
Page 2: ......
Page 30: ...24 Installation HP 328 HIT 4G This page intentionally left blank...
Page 42: ...Operation 36 HP 328 HIT 4G This page intentionally left blank...
Page 52: ...46 Modbus Communications HP 328 HIT 4G This page intentionally left blank...
Page 68: ...62 HIT 4 Communication Program HP 328 HIT 4G This page intentionally left blank...
Page 71: ...Appendix A Declaration of Conformity 65 HIT 4G HP 328 APPENDIX A DECLARATION OF CONFORMITY...
Page 72: ...66 Appendix A Declaration of Conformity HP 328 HIT 4G...