24
- 24 -
ALARM SIGNALS
10.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
10.1 List of alarms
Anomalies are shown on Display 2 during operation, see the description:
Chamber probe alarm:
temperature probe broken or interrupted.
Humidity probe alarm:
humidity probe broken or interrupted.
Internal core probe alarm
: core probe broken or interrupted (it is possible to use the oven without probe in
the core).
External core probe alarm:
core probe broken or interrupted or not inserted correctly (it is possible to
use the oven without probe in the core).
Board temperature alarm:
board overheated (over 70° C).
Motor alarm:
motor overheated.
No water alarm:
insufficient water supply.
EEP:
incorrect loading/updating software.
FLAM:
no power flame.
Vent alarm:
venting device malfunction.
OFFRUN alarm:
fast temperature rise.
Pressing the "PLUS" button for 5 seconds may temporarily stop the alarm. The message will reoccur
until resolution of the problem.
Contact the authorised service centre.
The authorised technician will identify the cause of the problem and restore proper
operation.
TROUBLESHOOTING
Whenever the appliance does not work properly, try to solve the less serious problems
using this table.
ANOMALY
POSSIBLE CAUSE
INTERVENTION
The appliance does not turn on.
•
The master switch is not con-
nected.
•
The circuit breaker or magnetic
circuit breaker has tripped
•
Connect the master switch.
•
Reset the circuit breaker or ma-
gnetic circuit breaker
Steam is not being generated
The water tap is closed
Open the water tap
Water does not drain from the
cooking compartment.
The drain is clogged.
•
Clean the drain filter.
•
Free the drain from residues.
The inner walls are covered with
limescale.
The water softener is not con-
nected or is empty
•
Connect the appliance to a water
softener.
•
Regenerate the water softener.
•
Descale the cooking com-
partment.
The cooking compartment is
stained.
•
Water quality
•
Ineffective detergent.
•
Insufficient rinsing.
•
Filter the water (see water sof-
tener).
•
Use the recommended deter-
gent.
•
Rinse once again.
The gas appliance will not turn on
•
Gas valve closed.
•
Air in the hose
•
Open the gas valve
•
Repeat the operation
No water
The water tap is closed
Open the water tap
Electronic components overheating
(Alarm board temperature)
Cooling fans obstructed
Free the air passage or clean the
filters
Filter cleaning message
Filter maintenance timer exceeded Proceed with cleaning (see 9.5
Periodic inspections)
If the problem cannot be resolved, turn the appliance off and shut all the supply valves.