![Hobart CLF26D-10 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/hobart/clf26d-10/clf26d-10_instruction-manual_2142090010.webp)
INSTRUCTION MANUAL FOR DISHWASHERS
Page 9 of 15
GB
TANK /
BOILER /
Thermostop time-out. For more information, refer to the chapter
“Adjustment and controls”. If the indication appears again, contact a
qualified technician.
TANK /
BOILER /
Tank loading time-out: the tank has not filled up. Try to turn off and
turn back on the machine and run a new loading. Check that the
overflow is present if it is necessary for machine operation.
If the indication appears again, contact a qualified technician.
TANK /
BOILER /
Tank probe broken (open). Contact a qualified technician.
TANK /
BOILER /
Tank probe broken (short-circuit). Contact a qualified technician.
TANK /
BOILER /
Boiler probe broken (open). Contact a qualified technician.
TANK /
BOILER /
Boiler probe broken (short-circuit). Contact a qualified technician.
TANK /
BOILER /
Boiler loading time-out: the boiler has not filled up. It is not possible to
rinse. Check that the water tap upline of the machine is open. Run a
new complete cycle. If the indication appears again, contact a qualified
technician.
TANK /
BOILER /
Tank temperature too high. Contact a qualified technician.
TANK /
BOILER /
Boiler temperature too high. Contact a qualified technician.
TANK /
BOILER /
Electromechanical safety: the safety thermostats of the boiler or tank
have tripped or the tank safety pressure switch has tripped. Contact a
qualified technician.
(*) these messages can be deactivated by a qualified technician on request.
Chap 5
MAINTENANCE
Completely empty the machine as described in the paragraph “Machine Emptying”,
turn off the electricity with the main external switch and close the external water
valve before starting any maintenance operation.
5.1
Cleaning and hygiene
To guarantee machine hygiene the routine (daily), weekly and yearly maintenance operations
indicated below must be regularly performed. Also carry out a periodical sanitising treatment with
suitable non-corrosive products available on the market.
5.2
Routine maintenance (daily)
When you notice residue of grime on the tank filter:
•
Remove and clean the racks, the overflow if present and the filter.
•
Do not use abrasive products or objects for cleaning the steel tank. Instead use a slightly soapy
damp cloth.
•
Do not use pressurised jets of water because they could damage the electric system.