TYPE OF FAILURE

POSSIBLE CAUSE

REMEDY

Poor wash result

Dishes or glasses

Rinse aid concentration too low.

Increase concentration (see operating

do not dry properly.

instructions).

Dishes still greasy.

1. Detergent concentration too low: increase

(see instructions).

2. Check if detergent is appropriate. If not choose

a stronger one.

3. Drain soiled water and refill machine.

Check pre-scrapping procedure.

Rack is not suitable for type of dishes

Use appropriate racks to create a sloping position

(sloping).

which allows water to drain away from cavities.

Dishes stay too long in the machine

Take out dishes as soon as cycle is completed

at the end of programme.

to enable them to dry.

Stripes and stains on

Rinse aid concentration too high.

Reduce quantity (see instructions).

dishes or glasses.

Hard water or high mineral content.

Check water quality.
Obtain details from local water authority.

Recommended values:
Ideal degree of hardness is 4° Clark.
Ideal conductivity value for glasses is max.
150 µS/cm and for dishes max. 400 µS/cm.

Rack is not suitable for type of dishes

Use appropriate racks to create a sloping position

(sloping).

which allows water to drain away from cavities.

Insufficient rinse aid concentration

Increase quantity (see instructions).

causes stains.

Machine with softener:

wrong type of salt used.

Use only granular salt.

Other malfunctions

Glasses are totally or

Surface of glasses is rough and

This is not caused by a malfunction on the

partially cloudy.

porous, this is called glass corrosion.

machine. Replace with new glasses.

Glass breakages.

Use of inappropriate dish or glass

Use appropriate racks.

racks.

AUXXT models only:

High pressure cleaning had been

Never use high pressure cleaning for glasses

activated.

and light dishes.

Machine suddenly stops

Machine is connected to a "maximum

Connect machine separately (call electrician).

during wash programme.

power supply unit" which cuts out the
energy consumer at a given point, or
machine is interlocked with another
energy consumer unit.

Blown site fuse.

Check site fuses.

If no button will be pressed during 

6

 hours, the machine switches off automatically without draining.

Follow the description below during the next switch on:

Push the 

ON

/

OFF

-button

 

.

Push the 

Drain

-button

 

 

and wait, until the machine is drained and switched off.

Restart the machine as described at chapter 

7

.

Summary of Contents for AMXXT Series

Page 1: ...REV 8 xx 04 07 2005 INSTALLATION OPERATION Glass and Dishwashers AMXXT AUXXT Series...

Page 2: ...e machine The Attention symbol is shown beside instructions that are essential for the safe operation of the machine Please read these passages thoroughly Liability Installations and repairs which are...

Page 3: ...on 4 2 Connections 4 3 Connecting of detergent pump 5 4 Controls 8 5 First run 9 6 Settings 10 7 Operation 11 8 Preview of temperatures 13 9 Switch off and cleaning the machine 14 10 Refilling the sof...

Page 4: ...60 335 the appliance must be connected to an equipotential conductor The connecting screw is located beside the cable inlet 1 Installation 1 1 Location Rear wall clearance not required For corner inst...

Page 5: ...he line flow pressure must not be less than 0 5 bar If the line flow pressure is above 10 bar provide pressure reducer at source Connect the union nut A 3 4 of the water supply hose with the site shut...

Page 6: ...ght or left tank Install detergent inlet fitting gasket B Connect a hose PVC 6mm outside x 4mm inside between outlet of the detergent pump and the detergent inlet B of the wash tank Tighten with hose...

Page 7: ...osing connection with tank wall Connect the plug C of the wire harness with the dosage pump max 100 VA Close control box and put panel s back into place Switch on main switch at site or put the plug i...

Page 8: ...button not possible within the first 5 seconds after cycle start By pushing and holding 3 sec the Start button high pressure mode will be activated permanently Drain button By pushing and holding 2 s...

Page 9: ...ner lid and fill the softener with 2 kg of Granular salt do not use salt tablets Fill up the softener with drinking water Clean seal and rim of softener lid carefully before closing the lid Close lid...

Page 10: ...nce with chemical suppliers recommendations 6 2 Adjustment of rinse agent dosage quantity Push Program button again The temperature indicator Rinse displays CH2 adjustment of the rinse agent dosage qu...

Page 11: ...t suction hose Push and hold Start button for 3 minutes approx By using external container with a longer suction hose hold the Start button about 6 minutes 7 Operation 7 1 Preparation Check correct po...

Page 12: ...on is not reached during the first wash cycle Therefore it is recommended doing the first wash cycle without dishes 7 2 Run Put racks into the machine and close hood The Start button illuminates blue...

Page 13: ...short break rinse starts automatically The machine continues with the chosen cycle time until switch off High pressure cleaning AUXXT models only Never use for cleaning glasses and light dishes breaka...

Page 14: ...in switch or unplug and close shut off valve at site 9 2 Cleaning daily Open hood and take out rack guides Take out strainers and flush Clean interior of machine Put strainers and rack guides back int...

Page 15: ...ndicator goes off with delay 11 Frost prevention In case of frost or longer operation pauses e g for seasonal operations the machine must be completely drained This should be carried out by after sale...

Page 16: ...er soiled Take out strainer empty and clean it Fine strainer soiled or obstructed Take out fine strainer If heavily soiled soak in a by lime vinegar solution Then clean it thoroughly until the pores a...

Page 17: ...appropriate racks to create a sloping position sloping which allows water to drain away from cavities Insufficient rinse aid concentration Increase quantity see instructions causes stains Machine with...

Page 18: ...As continued product improvement is a policy of HOBART specifications are subject to change without notice Printed in Germany AG 21247 C 07 05 PC...

Reviews: