Configuration
17
iPC-I 320 Manual, Version 2.8
JP25 leads the signals of the
second bus transceiver
to the 10-pin header
JP34.
Pin no.
JP25
Pin no. JP34
Signal
1
1
2
3
CAN Low
3
5
GND (via JP32)
4
7
5
9
6
2
GND (via JP33)
7
4
CAN High
8
6
9
8
VCC (via JP36)
10
10
With electrically isolated bus transceivers the signals GND and VCC are also
electrically isolated from the GND and VCC signals of the interface.
If the CAN protective circuit is assembled on the circuit board, the signals
CAN-Low and CAN-High are connected from JP15 (JP25) via the protective
circuit with CON2/3 (JP34).
3.3.2 Serial RS232 Interface
The serial interface can be optional assembled. The signals of the first RS232
interface connect with JP17, the signals of the second RS232 interface with
JP18. With the PC/104 version, only the first serial interface is supported.
Pin no.
JP17/JP18
Signal
Sub D9 pin
1
2
3
RxD
2
4
5
TxD
3
6
7
8
9
GND
5
10