Installation
6 (12)
2.2
Connectors
2.2.1 Power Connector
Connecting power with reverse polarity or using the wrong type of power
supply may damage the equipment. Make sure that the power supply is
connected correctly and of the recommended type.
The power connector consists of a 6-pin terminal block located on the top of the
unit. The unit can be supplied with power from two independent 12–48 VDC
power sources for redundancy using the inputs
PWR-1
and
PWR-2
.
See also
Technical Data, p. 10
regarding power supply requirements.
The power connector also includes a relay output,
Fault
, that can be used for
triggering an alarm in case of power failure (see the User Manual).
V1+
Power Input 1 +
V1-
Power Input 1 -
V2+
Power Input 2 +
V2-
Power Input 2 -
Fault
Relay output, NO, max 1 A @ 24 V
Chassis ground
Anybus
®
WLAN Access Point IP30 Startup Guide
SP2382 EN 1.1