Design Guide
Revision 1.12
1998-08-12
HMS F
IELDBUS
S
YSTEMS
AB
Page 10 (35)
3.1 Future use compatibility
3.1.1 Application interface (for future use)
The AnyBus module is accessed through the application connector. To achieve compatibility for future
AnyBus products a 34 pin connection should be implemented.
2.00 mm
2.00 m
m
34.00 m
m
3.00 mm
3
4
1
Figure 3. Application interface connector
Pin No.
Name
Function
1-32
See chapter 7.1
33
A10
Not used for DT module, reserved for address line 10
34
N.C.
Not connected
Table 2. Interface connector pin description
3.1.2 Mounting devices (for future use)
39.00m
m
2.50mm
11.00mm
39.75m
m
4.00mm
Hole A.
Hole C.
Hole B.
59.50mm
Figure 4. Mounting holes
A)
Conductive hole. Used to connect P.E. on carrierboard with fieldbus electronics.