Pin 31
/CE
DPRAM Chip Enable signal. From application to DPRAM. Active low.
Pin 32
/RESET
A
NY
B
US
D
ATA
T
RANSFER
reset signal. This signal resets and disables the modules functions. Active low.
7.3 Electrical Characteristics
All voltages measured with respect to device GND pin unless otherwise noted.
7.3.1 BUS Electronics Electrical Characteristics
Symbol
Description
Min.
Typ.
Max.
Unit
VCC
Supply voltage
4.75
5.00
5.25
V
I
IN
Input current
120
200
mA
Table 10. Electrical characteristics BUS electronics
7.3.2 Electronics Electrical Characteristics
Symbol
Description
Min.
Typ.
Max.
Unit
VCC
Supply voltage
4.75
5.00
5.25
V
I
IN
Input current
120
250
mA
Table 11. Electrical characteristics electronics
7.3.3 Serial Interface Electrical Characteristics
Not used by the parallel interface.
7.3.4 DPRAM Electrical Characteristics
Please see Appendix C for electrical characteristics of the DPRAM.
7.3.5 RESET Electrical Characteristics
Symbol
Description
Min.
Typ.
Max.
Unit
V
RESET
Reset active voltage
0
0.8
V
t
W
Reset pulse duration, minimum effective
500
ns