Emergency Operation:
•
Carry out this operation only when the remote controller is defective or lost.
•
When the emergency operation switch is pressed, a" Pi "sound starts once, which
means the start of this operation.
•
In this operation, it is not possible to change the settings of temperature and air flow speed, it is
also impossible to do an operation by the timer.
•
Follow the requirements below.
Test operation:
•
Use this switch in the test operation when the room temperature is less 16oC,
do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you
hear the "Pi" sound twice, release your finger from the switch, the cooling ope-
ration starts with the air flow speed setting "Hi".
Removal of the restriction of emergency or test operation:
•
Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the res-
triction of emergency or test operation to be removed.
•
When the remote controller is manipulated for the removal, then the selected operation by the remote controller.
* If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23ºC.
Heating when the room temperature at the start of operation is below23ºC.
Emergency operation and test operation
Room
temperature
Designated
temperature
Timer
mode
Air flow
speed
Operation
mode
More than 23ºC
26ºC
CONTINUOUS
AUTO
COOL
Less than 23ºC
23ºC
CONTINUOUS
AUTO
HEAT
OPERATION