![Hiwin MAGIC-01-14-EN-2207-MA Assembly Instructions Manual Download Page 24](http://html1.mh-extra.com/html/hiwin/magic-01-14-en-2207-ma/magic-01-14-en-2207-ma_assembly-instructions-manual_2140509024.webp)
Assembly instructions
Commissioning
HIWIN MAGIC Distance Measuring Systems
MAGIC-01-14-EN-2207-MA
Page
24
of
32
5.3
Voltage amplitude
Output voltage U of the encoder (1 V
ss
) depends on its distance from the magnetic tape. The
correlation between voltage amplitude U and encoder distance s is illustrated by Fig. 5.4, the
recommended range for the reading distance is marked in green.
Fig. 5.4: Voltage amplitude U over reading distance s
5.4
Reference switch
The reference switch must be connected according to Fig. 5.5.
Fig. 5.5: Circuit diagram of the optional reference switch
Explanation of symbols
Core colours
+ Power supply “+”
BN Brown
–
Supply voltage “0
V”
BK Black
Ā
Switching output / NC contact (NC)
BU Blue
6
Commissioning
Note:
Observe the assembly instructions of the other system components (e.g. linear motor, servo
amplifier)!
The following sequence must be observed when commissioning the distance measuring
system:
Connect encoder
Apply supply voltage (5
V)
Do not exceed the operating voltage, otherwise the encoder may be destroyed!
Check output signal e.g. with an oscilloscope