Assembly instructions
Product descriptions
HIWIN MAGIC Distance Measuring Systems
MAGIC-01-14-EN-2207-MA
Page
10
of
32
3.3
Connections
The distance measuring system is connected to a higher-level control system (e.g. servo drive)
with the cable permanently mounted on the encoder. It is supplied with a low voltage of 5
V.
The cable can be supplied with open ends (see Fig. 3.5) or optionally pre-assembled with a
round plug coupling (see Fig. 3.6).
Fig. 3.5: Cable with open ends
Fig. 3.6: Cable with coupling (optional)
3.4
Reference switch
The MAGIC encoder provides index signals at intervals of 1
mm. A reference switch ("cam
switch") is required to define a zero point.
HIWIN offers an inductive proximity switch for this purpose (see Fig. 3.7).
Fig. 3.7: Reference switch on bracket
3.5
Scope of delivery
Depending on customer requirements, the MAGIC and MAGIC-PG distance measuring systems
are offered in different forms and scopes.
Individual components can be supplied for retrofitting existing linear guide systems. HIWIN also
offers the distance measuring systems installed in linear guides as a complete system.
The standard scope of delivery and the optional accessories are shown in Table 3.1. You will
find the order code for systems in section 9 Spare parts and accessories.
Table 3.1: Overview of standard scope of delivery and optional accessories
Distance measuring system
MAGIC
MAGIC-PG
Encoder
Select cable length
Select cable length
Magnetic tape (including cover
strip)
Select length
Select length
Type of encoder with coupling
Optional
Optional
Reference switch
Optional
Optional
Screw set for MAGIC-PG
Not suitable
Standard scope of delivery