12
hivolt.de
GmbH & Co. KG
Oehleckerring
40
∙
D-22419
Hamburg
∙
Germany
∙
+49 40 537122-0
∙
+49 40 537122-99
∙
∙
www.hivolt.de
4.9
Analog Control X1
Connector type:
D-Sub 25-pin female connector
Screwlock: UNC
4-40
Pin Signal
Direction Function
1
+VS_IN
I
Supply v24V
DC
2
+VS_IN
I
Supply v24V
DC
3
IL_IN
I
Interlock / bridge to X1.IL_R
4
SDNRST_D
I
Control signal: TTL-H for 0.5s => Shutdown Reset;
Caution: This reactivates the HV output after a shutdown!
5
STAT1
O
Status output; 5V level; R
O
= 1k
Ω
; H == no shutdown
6
INP
I
Differential analog input; positive
7
VOAV
O
Analog output: voltage monitor
8
IOAV
O
Analog output: current monitor
9
GPI1
I
Digital input; TTL level
10 GPI2
I
Digital input; TTL level
11 GPI3
I
Digital input; TTL level
12 GPI4
I
Digital input; TTL level
13 +5VX
O
Auxiliary voltage 5V; max. 10mA
14 GND
-
Supply voltage GND
15 GND
-
Supply voltage GND
16 IL_R
O
Interlock / bridge to X1.IL_IN
17 ENABLE
I
Control signal: TTL-H => enables HV sources and output stages *;
Caution: This activates the HV output!
18
n. c.
19 INN
I
Differential analog input; negative
20 GND
-
Signal
ground
21 X1_CTLn
I
Control signal: 5V level; L => function X1.ENABLE active;
internal pullup 10k
Ω
22 GPO1
O
Digital output; 5V level; R
O
= 1k
Ω
23 GPO2
O
Digital output; 5V level; R
O
= 1k
Ω
24 GPO3
O
Digital output; 5V level; R
O
= 1k
Ω
25 GPO4
O
Digital output; 5V level; R
O
= 1k
Ω
*
The
ENABLE
signal is only effective when the input
X1_CTLn
is set to L.
Switching the output off via the
ENABLE
control input must not be used as a safety-relevant
function!
ENABLE OFF
->
ENABLE ON
may not be switched faster than 5 s in each level, otherwise
shutdown will be triggered.