CONFIDENTIAL 50
Maintenance Parts Replacement Procedures
Parts Name MTR CAM PM 15 22OHM BIP P110S
Parts No.
17.MCP25.BM1
Tools
Screwdriver
Procedure No.
Maintenance part: MTR CAM PM 15 22OHM BIP P110S (CAM MOTOR)
[Step 1] Remove the ASSY_CASE_LEFT, ASM_ID_CASE_RIGHT and CHASSIS ASSY according
to the
Procedure No. 1
.
[Step 2] Remove the flat cable and connector of MTR CAM PM 15 22OHM BIP P110S that connects
with MAIN BD.
[Step 3] Remove 2 screws form left side then and take MTR CAM PM 15 22OHM BIP P110S out.
[Step 4] Assemble it in the reverse order of the disassembly procedure.