IOM_CCHIBA-CSTIBA_301_207925_170706_EN 

 

CCHIBA/CSTIBA 

SPLIT HORIZONTAL INVERTER UNITS  
PACKAGED AIR-AIR 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(1) Cooling Rated Conditions:

 Internal temperature DB: 27ºC, Internal temperatura WB: 19ºC 

(2) Heating Rated Conditions:

 Internal temperature DB: 20ºC  

(3)  GWP:

  Global  warming  potential  (climatic)  of  1  kg  of  greenhouse  gas  relative  to  1  kg  of  CO

2

calculated in terms of 100-year warming potential. 

(4) 

Only the outdoor 

units which has serial “FLARE” valve (not from option) are charged with 

refrigerant, the rest come Pre-Charged with dry nitrogen.

 

 

 

CSTIBA 

301 

 

CAPACITIES 

Rated Cooling Capacity (1) 

kW 

7.4 

Cooling Capacity (20 

– 100 – 120 

Hz) 

kW 

1.2 

– 7.4 – 8.1 

Rated Heating Capacity (2) 

kW 

7.5 

Heating Capacity (20 

– 100 – 120 Hz) 

kW 

1.3 

– 7.5 – 8.3 

Coeficient EER 

 

>8 

SEER 

 

4.6 

Class 

 

SCOP (Warm Zone) 

 

4.1 

Class 

 

A+ 

Sound Power at Low Speed 

dBA 

34 

Sound Power at Medium Speed 

dBA 

40 

Sound Power at High Speed 

dBA 

50 

 

REFRIGERANT

 

Type 

 

R-410A 

Global Warming Potential (GWP) (3) 

 

2088 

Frigorific Connection Liquid Line 

“ 

3/8 

Frigorific Connection Gas Line 

“ 

1/2 

Charge (4) 

kg 

 

DRAINAGE 

Condensate Pump 

 

YES 

Available Pressure 

mm. W.G 

400 

 

INDOOR HEAT EXCHANGER

 

Type 

 

Aluminum Fins and Copper Pipes 

Frontal Surface 

m

2

 

0.360 

Fins Size 

mm 

2.1 

Piping Diameter 

mm 

7.2 

 

ELECTRICAL SPECIFCATIONS 

Power Supply 

V / phases / 

Hz 

220-240 / I / 50 

Electric Connections 

mm² 

2 x 1.5 + T 

Interconnection with Termostat 

 

Twisted Pair + Shielded 

Interconnection Between Units 

 

Twisted Pair + Shielded 

 

INDOOR FAN

 

Diameter 

mm 

380 

Voltage 

220-240 / I / 50 

Motor Power 

kW 

0.13 

Transmission 

 

AC Integrated Motor 3 Speeds 

Rated Airflow 

m

3

/h 

840 / 1000 / 1200 

 

DIMENSIONS AND WEIGHT

 

Length 

mm 

830 

Width 

mm 

830 

Height 

mm 

300 

Weight 

kg 

31 

Summary of Contents for CCHIBA 301

Page 1: ...R AIR SPLIT HORIZONTAL INVERTER UNITS Models 301 Cooling Capacities from 1 3 kW to 8 3 kW Heating Capacities from 1 2 kW to 8 1 kW HEAT PUMP Installation Operation and Maintenance Manual IOM_CCHIBA CS...

Page 2: ...efficiency adaptability usability and practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to contribute solutions almost tailored to each p...

Page 3: ...GGING 7 STORAGE 7 INSTALLATION LOCATION 8 SERVICE AREA MM 8 CCHIBA 301 8 CSTIBA 301 8 WEIGHT DISTRIBUTION KG 9 UNIT SETTLEMENT 9 START UP 10 OPERATION LIMITS 11 DRAINAGE 12 AIR DUCTS 12 COMPRESSOR LUB...

Page 4: ...e or places of installation of the units check means and tools to use etc It is not possible to anticipate each and every one of the potential circumstances of danger in this manual Respect the local...

Page 5: ...warranty expiration Refrigerant This product is hermetically sealed and contains R 410A which is a HFC fluorinated greenhouse gas REGULATIONS AND CERTIFICATIONS ISO 9001 2015 CERTIFICATION HILPUS AIRE...

Page 6: ...d in the Installation operation and maintenance instructions as well as the ones indicated in labels of the unit Do not forget to strictly follow any other safety codes Use safety glasses work gloves...

Page 7: ...it s in accordance with local power supply In case of any flaw or anomaly detected please contact HITECSA RIGGING Before moving the unit make sure that all panels are well fixed Raise and set down the...

Page 8: ...operation Reserve a minimum service area Choose a place free of dust or any other foreign material that could clog or damage the condenser coil The location should also be a place that cannot be flood...

Page 9: ...BUTION kg UNIT SETTLEMENT Make sure that the unit is correctly levelled The bed frame should be strong and solid enough to support the weight of the machine Verify that the water drain of the indoor i...

Page 10: ...m 300 mA to prevent supply cuts caused by the differential switch Check the following points Electrical connections are well tightened Panels are firmly secured with screws There are no oil or refrige...

Page 11: ...Main power supply of the unit should same as the data shown on the nameplate HITECSA will not be held responsible for damages resulted from non observance of the above Always use the wiring diagram se...

Page 12: ...ith proper dimensions AIR DUCTS Air duct dimensions will be determined according to the airflow and available static pressure Ducts must be designed by qualified technical people Use ducts made of non...

Page 13: ...t EER 8 SEER 4 6 Class B SCOP Warm Zone 4 1 Class A Sound Power dBA 70 REFRIGERANT Type R 410A Global Warming Potential GWP 3 2088 Number of Refrigerant Circuits 1 Frigorific Connection Liquid Line 3...

Page 14: ...eficient EER 8 SEER 4 6 Class B SCOP Warm Zone 4 1 Class A Sound Power at Low Speed dBA 34 Sound Power at Medium Speed dBA 40 Sound Power at High Speed dBA 50 REFRIGERANT Type R 410A Global Warming Po...

Page 15: ...15 IOM_CCHIBA CSTIBA_301_207925_170706_EN CCHIBA CSTIBA SPLIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR DIMENSIONS CSTIBA 301 CONSTRUCTION DETAILS 1 Drain 2 Cooling Connections 3 Electrical Panel...

Page 16: ...LIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR CCHIBA 301 CONSTRUCTION DETAILS 4 Compressor 5 Outdoor Heat Exchanger 6 Electrical Panel 7 Outdoor Turbine 8 Outdoor Drain Diameter 3 4 Male 9 Cooling Co...

Page 17: ...on between both indoor and outdoor units Pressure drop of the line Circulation speed of the refrigerant Refrigerant mass DISCHARGE LINES In heat pump operation the low pressure line works as high pres...

Page 18: ...of refrigerant in the system R410A Liquid line 3 8 1 2 5 8 3 4 7 8 1 1 8 1 3 8 Gas quantity gr m 52 100 166 244 341 538 867 Fasten the tubes to fixe elements by means of braces to avoid vibration Car...

Page 19: ...right pipe diameter you can use the immediately lower diameter The system will function normally only with a slight capacity reduction Units CSTIBA CCHIBA are supplied with nitrogen charge at a pressu...

Page 20: ...out a leak test Leak detectors usually employed with CFC and HCFC cannot be used with R410a due to chlorine in its composition A leak detector for R134A can be used but the sensitibity will be lower...

Page 21: ...Check for oil refrigerant leaks noises or system s vibrations Take measurements of temperatures and pressures of components and record them on the maintenance form Electrical circuit Make sure that al...

Page 22: ...xiation will occur An individual exposed to high concentrations of R410A must be given medical attention immediately Adequate ventilation must be provided at all times Recommendations Semiotics or sup...

Page 23: ...w 52 C Protective Clothing Wear overalls protective gloves and goggles or a mask Accidental Release Measures IIt is important to wear protective clothing and a respirator Stop the source of the leak i...

Page 24: ...24 IOM_CCHIBA CSTIBA_301_207925_170706_EN CCHIBA CSTIBA SPLIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR We reserve the right to add modifications without prior notice...

Reviews: