IOM_CCHIBA-CSTIBA_301_207925_170706_EN 

 

CCHIBA/CSTIBA 

SPLIT HORIZONTAL INVERTER UNITS  
PACKAGED AIR-AIR 

INTRODUCTION 

 

Purpose of the Manual 

 

 

This manual and the instruction documents of refrigeration lines, wiring diagrams and any other attached 
documents, have been written to allow a correct installation, set up and maintenance of the unit. 
Therefore it is essential to read the instructions with due attention. Verify all the necessary information for 
the correct installation of the system is included in the manuals supplied with this unit and / or the rest of 
the indoor units, accessories, etc. Otherwise, the manufacturer declines any responsibility for any 
damage to persons or things, as a result of improper use of the unit and/or failure to observe these 
instructions. 

 
Preservation Manual 

 

This manual and the electric diagram of the unit must be retained and remain available to the operator for any further 
consultation. 
 

Updating the Data 

 

The continuous improvement in design and performance to which we are committed gives us the right to modify the 
specifications of our products without prior notice. 

 

 

Electrical Network 

 

 

Check that electrical network features are in accordance to data shown in the data nameplate of the unit. 

 
Local Safety Regulations 

 

Observe and analyze all possible causes of accidents that may arise in the place or places of installation of the units, 
check means and tools to use, etc. It is not possible to anticipate each and every one of the potential circumstances of 
danger in this manual. Respect the local security standards during installation. 

 

Principles of Security on Installation 

 

The unit is designed and built in a way that does not pose a risk to the health and safety of people. Appropriate project 
solutions have been adopted to eliminate the possible causes of risk in the installation. 

 
Packaging and Replacement of Equipment 

 

 

The packaging material (plastic bags, insulating materials, nails, etc.) is a potential source of danger and 
should be kept out of the reach of children and properly recycled according to local safety regulations. 
This product should not be mixed with household waste at the end of its life. Due to the refrigerant, oil 
and other components contained in this product, it must be dismantled by professional installers in 
accordance with current regulations. 

 

Use 

 

The unit will be used only for the reason has been conceived. Any other use does not imply any kind of compromise or 
link for the manufacturer. 

 
Incorrect Operation 

 

In case of breakdowns or operation faults, turn off unit. 
 

Periodic Inspections and Maintenance 

 

 

Carry out periodic inspections to detect possible damaged or broken pieces. If they are not repaired it 
could result in damage to people or stuff. Before executing any maintenance operation, cut off the unit 
power supply.  

All operations must be carried out in accordance with local safety regulations. 

 
 
 
 

 

Summary of Contents for CCHIBA 301

Page 1: ...R AIR SPLIT HORIZONTAL INVERTER UNITS Models 301 Cooling Capacities from 1 3 kW to 8 3 kW Heating Capacities from 1 2 kW to 8 1 kW HEAT PUMP Installation Operation and Maintenance Manual IOM_CCHIBA CS...

Page 2: ...efficiency adaptability usability and practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to contribute solutions almost tailored to each p...

Page 3: ...GGING 7 STORAGE 7 INSTALLATION LOCATION 8 SERVICE AREA MM 8 CCHIBA 301 8 CSTIBA 301 8 WEIGHT DISTRIBUTION KG 9 UNIT SETTLEMENT 9 START UP 10 OPERATION LIMITS 11 DRAINAGE 12 AIR DUCTS 12 COMPRESSOR LUB...

Page 4: ...e or places of installation of the units check means and tools to use etc It is not possible to anticipate each and every one of the potential circumstances of danger in this manual Respect the local...

Page 5: ...warranty expiration Refrigerant This product is hermetically sealed and contains R 410A which is a HFC fluorinated greenhouse gas REGULATIONS AND CERTIFICATIONS ISO 9001 2015 CERTIFICATION HILPUS AIRE...

Page 6: ...d in the Installation operation and maintenance instructions as well as the ones indicated in labels of the unit Do not forget to strictly follow any other safety codes Use safety glasses work gloves...

Page 7: ...it s in accordance with local power supply In case of any flaw or anomaly detected please contact HITECSA RIGGING Before moving the unit make sure that all panels are well fixed Raise and set down the...

Page 8: ...operation Reserve a minimum service area Choose a place free of dust or any other foreign material that could clog or damage the condenser coil The location should also be a place that cannot be flood...

Page 9: ...BUTION kg UNIT SETTLEMENT Make sure that the unit is correctly levelled The bed frame should be strong and solid enough to support the weight of the machine Verify that the water drain of the indoor i...

Page 10: ...m 300 mA to prevent supply cuts caused by the differential switch Check the following points Electrical connections are well tightened Panels are firmly secured with screws There are no oil or refrige...

Page 11: ...Main power supply of the unit should same as the data shown on the nameplate HITECSA will not be held responsible for damages resulted from non observance of the above Always use the wiring diagram se...

Page 12: ...ith proper dimensions AIR DUCTS Air duct dimensions will be determined according to the airflow and available static pressure Ducts must be designed by qualified technical people Use ducts made of non...

Page 13: ...t EER 8 SEER 4 6 Class B SCOP Warm Zone 4 1 Class A Sound Power dBA 70 REFRIGERANT Type R 410A Global Warming Potential GWP 3 2088 Number of Refrigerant Circuits 1 Frigorific Connection Liquid Line 3...

Page 14: ...eficient EER 8 SEER 4 6 Class B SCOP Warm Zone 4 1 Class A Sound Power at Low Speed dBA 34 Sound Power at Medium Speed dBA 40 Sound Power at High Speed dBA 50 REFRIGERANT Type R 410A Global Warming Po...

Page 15: ...15 IOM_CCHIBA CSTIBA_301_207925_170706_EN CCHIBA CSTIBA SPLIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR DIMENSIONS CSTIBA 301 CONSTRUCTION DETAILS 1 Drain 2 Cooling Connections 3 Electrical Panel...

Page 16: ...LIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR CCHIBA 301 CONSTRUCTION DETAILS 4 Compressor 5 Outdoor Heat Exchanger 6 Electrical Panel 7 Outdoor Turbine 8 Outdoor Drain Diameter 3 4 Male 9 Cooling Co...

Page 17: ...on between both indoor and outdoor units Pressure drop of the line Circulation speed of the refrigerant Refrigerant mass DISCHARGE LINES In heat pump operation the low pressure line works as high pres...

Page 18: ...of refrigerant in the system R410A Liquid line 3 8 1 2 5 8 3 4 7 8 1 1 8 1 3 8 Gas quantity gr m 52 100 166 244 341 538 867 Fasten the tubes to fixe elements by means of braces to avoid vibration Car...

Page 19: ...right pipe diameter you can use the immediately lower diameter The system will function normally only with a slight capacity reduction Units CSTIBA CCHIBA are supplied with nitrogen charge at a pressu...

Page 20: ...out a leak test Leak detectors usually employed with CFC and HCFC cannot be used with R410a due to chlorine in its composition A leak detector for R134A can be used but the sensitibity will be lower...

Page 21: ...Check for oil refrigerant leaks noises or system s vibrations Take measurements of temperatures and pressures of components and record them on the maintenance form Electrical circuit Make sure that al...

Page 22: ...xiation will occur An individual exposed to high concentrations of R410A must be given medical attention immediately Adequate ventilation must be provided at all times Recommendations Semiotics or sup...

Page 23: ...w 52 C Protective Clothing Wear overalls protective gloves and goggles or a mask Accidental Release Measures IIt is important to wear protective clothing and a respirator Stop the source of the leak i...

Page 24: ...24 IOM_CCHIBA CSTIBA_301_207925_170706_EN CCHIBA CSTIBA SPLIT HORIZONTAL INVERTER UNITS PACKAGED AIR AIR We reserve the right to add modifications without prior notice...

Reviews: