Advanced System Set Up
The system will be set to its default parameters when powered on for the fi rst
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
Safet y T imer
O N 1 20Mi n
Res t T ime
CHG>DCH G 1 0Min
Capacit y C ut-Off
O N 5 000mAH
Temperatur
e U nit
C elsius
Tem p C ut-Of f
O N 5 0
°
C 1 22
°
F
This p rogram sets the maximum charge
capacity that will be supplied to the battery
during charge. If the delta peak voltage is
not detected nor the safety timer expired by
any reason, t his feature will automatically
stop the process at t he selected capacity
value.
When you start a charge process, t he
integral safety timer automatically s tarts
running at t he s ame time. This i s
programmed to p revent overcharge the
battery i f it p roves to be faulty, or i f the
termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to a llow a full charge of
the battery.
The battery's internal chemical reaction will
cause the temperature of t he battery t o
rise. If the temperature limit is reached, the
process will be terminated.
OFF/
ON
(
100-50000 mAh)
ITEM
SELECTION
DESCRIPTION
OFF/
ON
(
1-720 Min
)
OFF/
ON
(20 C/68 F -
80 C/176 F
)
Celsius
Fahrenheit
1-60Min
A rest t ime allowing the battery t o cool
down between charging/discharging cycle.
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
Safet y T imer
O N 1 20Mi n
Res t T ime
CHG>DCH G 1 0Min
Capacit y C ut-Off
O N 5 000mAH
Temperatur
e U nit
C elsius
Tem p C ut-Of f
O N 5 0
°
C 1 22
°
F
This p rogram sets the maximum charge
capacity that will be supplied to the battery
during charge. If the delta peak voltage is
not detected nor the safety timer expired by
any reason, t his feature will automatically
stop the process at t he selected capacity
value.
When you start a charge process, t he
integral safety timer automatically s tarts
running at t he s ame time. This i s
programmed to p revent overcharge the
battery i f it p roves to be faulty, or i f the
termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to a llow a full charge of
the battery.
The battery's internal chemical reaction will
cause the temperature of t he battery t o
rise. If the temperature limit is reached, the
process will be terminated.
OFF/
ON
(
100-50000 mAh)
ITEM
SELECTION
DESCRIPTION
OFF/
ON
(
1-720 Min
)
OFF/
ON
(20 C/68 F -
80 C/176 F
)
Celsius
Fahrenheit
1-60Min
A rest t ime allowing the battery t o cool
down between charging/discharging cycle.
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
Advanced System Set Up
[
cont.]
ITEM
SELECTION
DESCRIPTION
N i M H S e n s i t i v i t y
D . P e a k D
e f a u l t
Default: 4mV/Cell
3-15mV/Cell
This program is for NiMH/NiCd
batteries
only. When t he charger detects that t he
delta peak v alue has r eached t he v alue
set by the user, the battery will read fully
charged.
N i C d S e n s i t i v i t y
D . P e a k D
e f a u l t
K e y B e e p
ON
B u z z e r
ON
OFF/ON
A beep sounds w ith the press o f each
button t o confirm your action. The beep
or m elody sounded a t various t imes
during operation t o alert different mode
changes.
B a l . C o n n e c t i o n
ON
OFF/ON
For increased s afety when charging
Lithium batteries, connect t he b alance
wire of the battery t o balance sockets in
any mode, whether F ast C harge o r
Storage M ode. This f unction m ay be
disabled.
L o a d F
a c t o r y S e t
En
t e r
Press ENTER to load the factory
default settings.
V e r s i o n
H W : 1 . 0 0 F
W : 1 . 1 0
Indicates the hardware and firmware
version.