11
The Cycle Data display shows the charged-in and
discharged capacity, as well as the maximum battery voltage
reached during charging, and the average battery voltage
during discharging of all completed cycles. Data for up to ten
cycles can be viewed; the cycle is selected using the “+” or
“-” buttons. Recorded data can only be viewed at the end of
a cycle. To erase the data, either switch the charger off or
connect a new battery.
C: = Charge D: = Discharge
The BID Edit menu is where the parameters for charging
or discharging batteries are defined. The corresponding
settings are then stored BID chip or key.
(See Page 20 for working with the BID system)
On the BID Info menu, if a system is connected to either
channel, the data stored on the chip is displayed on-screen.
You can scroll through the data stored on the BID chip or key
by pressing the + or - buttons.
BID Edit [ 20/6/2016 ]
LiPo 7.4 V
2000mAh
Chg Current :
2.0mA
dChg Current :
1.0mA
dChg Volt :
3.2 V/C
TVC Volt :
4.20 V
Save to BID
[ BID Info ]
LiPo 7.4 V
2000mAh
Last Chg Capa :
0mAh
Max ChgCapa :
0mAh
Num ChrgCycles :
0
Last dChrgCaps :
0mAh
Max dChrgCaps :
v0mAh
STOP/ESC
button
[ Cycle Data ]
No
Capacity
Voltage
1 C:
0mAh
11.358 V
D:
0mAh
0.000 V
2 C:
0mAh
11.412 V
D:
0mAh
0.000 V
3 C:
0mAh
0.000 V
D:
0mAh
0.000 V
IF A BID CHIP OR BID KEY IS CONNECTED TO EITHER CHANNEL, THE MEMORY NAME
AND CYCLE DATA MENUS ARE REPLACED BY THE BID EDIT AND BID INFO MENUS
RESPECTIVELY.
After connecting the battery, you are now ready to setup the charger to charge your specific type of battery.
When the charger is first powered on, the Memory Name menu will be displayed. The default mode of the
charger is set for a 2 Cell 2000 mAh Lithium Polymer battery. If this is not the battery you plan on working
with, then you will need to make changes to the operation programming based on the following instruction.
Note